Model reference

Amana VRCF30-U01A/P69210-4C

Air Conditioner

1 document34 error codes6 service modes

Available documentation

Tech Sheet

  • Tech Sheet W1030148212 pg
    Covers this model
MyPros+ Max

Diagnose your Amana VRCF30-U01A/P69210-4C.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (34)

CodeMeaning
AFRestricted air flow condition exists.CALL SErvAmperage monitoring system on H.VDoorDoor Interlock Primary Switch fault.Err1Failed H.VErr2Failed H.VErr3Failed H.VErr4Failed H.VErr5Shorted Touch Panel.Err6Failed H.VF:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (only appears in diagnostic test mode).F:31Low voltage condition (less than 30 V) has been detected (appears ONLY in…F:50No voltage detected at the water valve relay (steam model only, only appears in…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).
View all 34 error codes

Service modes (6)

  • CALL SErv Reset["Unit must be in OFF condition or INITIAL power up mode.","Oven door must be closed.","Press…
  • Customer-Focused Drying Mode Adjustment["With the dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","The…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
  • Service Test Mode["Unit must be in OFF condition or INITIAL power up mode.","Oven door must be closed.","Press…

Full entry steps, exit procedures, and test sequences are available in Max.