Error codes (53)
CodeMeaning
afLow inlet air flow condition detected at installation (Amana models only).f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20Heater failuref:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (Amana models only, appears ONLY in Diagnostic Test…f:25Inlet thermistor is shorted (Amana models only, appears ONLY in Diagnostic Test…f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (Amana models only, appears ONLY in…f:31L2 line voltage errorf:50Water valve failuref:70No communication between the machine control and the console electronics.f:71No communication between the machine control and the console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).f1 e1Primary control failure.F1E1Primary control failure.F1E4MW Relay Error 0f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.View all 53 error codes
f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open.F3E2Exhaust thermistor has shorted.F3E3Meat probe NTC thermistor failure.F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF3E8IR sensor failuref4 e4Low line voltage detected.F4E1Cavity NTC thermistor failure.F4E3Hood NTC failureF4E4Humidity sensor failureF4E9MW relay synchro Error 1F4EAToast NTC thermistor failure.F5E2Open door error.F6E1ACU/HMI communication faultF7E9Vent error.f8 e1No voltage detected at the water valve relay (steam models only)F8E1No voltage detected at the water valve relay (steam models only)FDE3Hood Fan relay failure.FDE4MWO cooling fan failure.l2Low line voltage (less than 30V) detected at installation.pfPower failure occurred while the dryer was running.
Service modes (13)
- Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
- Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
- Demo ModePress Settings repeatedly to reach Demo Mode submenu -> 'DEMO Press 1-Enable' scrolls on display ->…
- Diagnostic Test Mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only Done/Dry/Clothes…
- Diagnostics Mode["Press Settings
- Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
- Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
- Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
- Manual Load Test1. Dryer must be in standby mode. 2. Select any one button except Pause/Cancel and Controls…
- Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
- Service Diagnostics Mode["Press Settings to initiate Diagnostics.","Press the numeric keys in the sequence…
- User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
Full entry steps, exit procedures, and test sequences are available in Max.