Model reference

Amana C10B/P60330-88W

Freezer

53 error codes13 service modes
MyPros+ Max

Diagnose your Amana C10B/P60330-88W.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (53)

CodeMeaning
afLow inlet air flow condition detected at installation (Amana models only).f:01Primary control failure.f:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).f:20Heater failuref:22Outlet thermistor is open.f:23Outlet thermistor has shorted.f:24Inlet thermistor is open (Amana models only, appears ONLY in Diagnostic Test…f:25Inlet thermistor is shorted (Amana models only, appears ONLY in Diagnostic Test…f:26Motor drive system failure.f:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).f:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).f:30Restricted air flow condition exists (Amana models only, appears ONLY in…f:31L2 line voltage errorf:50Water valve failuref:70No communication between the machine control and the console electronics.f:71No communication between the machine control and the console electronics.f:72Console electronics failure (F:72 through F:78).f:73Console electronics failure (F:72 through F:78).f:74Console electronics failure (F:72 through F:78).f:75Console electronics failure (F:72 through F:78).f:76Console electronics failure (F:72 through F:78).f:77Console electronics failure (F:72 through F:78).f:78Console electronics failure (F:72 through F:78).f1 e1Primary control failure.F1E1Primary control failure.F1E4MW Relay Error 0f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Stuck button or user interface mismatch (keypad/user interface failure)f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.
View all 53 error codes

Service modes (13)

  • Customer-Focused Drying Mode Adjustment["Ensure dryer is in standby mode.","Press and hold the TEMP button for more than 6…
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)1
  • Demo ModePress Settings repeatedly to reach Demo Mode submenu -> 'DEMO Press 1-Enable' scrolls on display ->…
  • Diagnostic Test Mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only Done/Dry/Clothes…
  • Diagnostics Mode["Press Settings
  • Displaying Inlet Air Flow Diagnostic (Amana Electric Models Only)["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Displaying Line Voltage Diagnostic["Enter the Diagnostic Test Mode.","Wait for the 5 second delay and cycle through any saved fault…
  • Inlet Air Flow Diagnostic (Amana Electric Models Only)After entering the Diagnostic Test Mode and cycling through saved fault codes, press the Wrinkle…
  • Line Voltage DiagnosticAfter entering the Diagnostic Test Mode and cycling through saved fault codes, press the Cycle…
  • Manual Load Test1. Dryer must be in standby mode. 2. Select any one button except Pause/Cancel and Controls…
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE or…
  • Service Diagnostics Mode["Press Settings to initiate Diagnostics.","Press the numeric keys in the sequence…
  • User Interface/Control System Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax