Model reference
Amana GL105E-R3/P96381-6F
Furnace
6 documents22 error codes14 service modes
Available documentation
Tech Sheet
- Tech Sheet 8563818 Rev A16 pg
- Wiring Diagram - W10668584 - Rev A8 pg
Tech Tip
- cookingguidelabel-8205592-fr.pdf1 pg
Installation Guide
- Instrucciones de instalacion56 pg
- Installation Instructions12 pg
- Installation Instructions16 pg
MyPros+ Max
Diagnose your Amana GL105E-R3/P96381-6F.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (22)
CodeMeaning
:Power failure indication; the colon is displayed on the screen after a power…E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF1E1Indicates a CCU (Cycle Control Unit) problem.F2Touch panel failure.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F6MW relay failure (Relay 4903 on PCBA); relay contact may have welded closed.F6E1Communication error from UI to CCU; communication between CCU and UI has not…F6E2Communication error from CCU to UI; communication between CCU and UI has not…L2Low L2 voltage (less than 50V) detected at the CCU.PFPower failure occurred while the dryer was running.Service modes (14)
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- Customer-Focused Dryness Level Adjustment1
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Software Version Display1
- Touch Panel and PCBA Self-Diagnostic Test Mode["Press and hold the CANCEL/OFF button while opening the door.","While still holding the CANCEL/OFF…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana furnace models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass