Model reference
Amana CRS50/P77075-4M
Microwave
3 documents32 error codes11 service modes
Available documentation
Service Manual
- Service Manual - 1602292434 pg
- Service Manual - 1602696933 pg
Tech Tip
- Instruction Sheet - 39800578 pg
MyPros+ Max
Diagnose your Amana CRS50/P77075-4M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (32)
CodeMeaning
AFRestricted air flow condition exists.E-20Keyboard assembly fault indicating a failed control circuit or membrane switch…E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchErr1Cavity temperature limit reached.Err2Sensor shorted.Err3Sensor open.F:01Primary control failure.F:02Stuck button or user interface mismatch (only appears in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (only appears in diagnostic test mode).F:25Inlet thermistor is shorted (only appears in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (only appears in diagnostic test mode).F:29Moisture sensor strip has shorted (only appears in diagnostic test mode).F:30Restricted air flow condition exists (only appears in diagnostic test mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (steam model only, only appears in…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).Service modes (11)
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- Customer-Focused Drying Mode Adjustment["With the dryer in standby mode, press and hold the Dryness Level button for 5 seconds.","The…
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Inlet Air Flow Diagnostic (Electric Models Only)["Enter Diagnostic Test Mode and wait for 5-second delay.","Cycle through any saved fault…
- Line Voltage Diagnostic["Enter Diagnostic Test Mode and wait for 5-second delay.","Cycle through any saved fault…
- Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Done…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass