Model reference
Amana RC-14TD/P75750-3M
Microwave
3 documents43 error codes23 service modes
Available documentation
Tech Sheet
- Tech Sheet - W11467195 - Rev B24 pg
- techsheet-w10420006-reva_W1042000656 pg
Service Flash
- Service Update First HALF—200994 pg
MyPros+ Max
Diagnose your Amana RC-14TD/P75750-3M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (43)
CodeMeaning
AFRestricted/low air flow detected that may affect dryer performance.f1 e1Primary control failure.F1 E4UIC (User Interface Control) fault detected.F1 E6Voltage input fault detected.F1 E7Voltage input fault detected.F1E1Indicates a Cycle Control Unit (CCU) problem.f2 e1Stuck button or user interface mismatch (only appears in service diagnostic…F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2UI software error; UI cannot read EEPROM software.f3 e1Exhaust thermistor is open.f3 e2Exhaust thermistor has shorted.f3 e6Moisture sensor strip is open (only appears in service diagnostic mode).f3 e7Moisture sensor strip has shorted (only appears in service diagnostic mode).F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms)F3E4Inlet thermistor is shorted; temperature above 760°F (<20 ohms)F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is openF3E7Moisture sensor strip has shortedF4E1No voltage detected at the heater relayF4E3Restricted air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5 E1Dryer door circuit error.F6 E1Communication failure between ACU and UICF6E1Communication between the CCU and UI has not been detected (UI to CCU).F6E2Communication between the CCU and UI has not been detected (CCU to UI).F7 E6Dryer motor circuit error.F7 E8Dryer motor sense error.f8 e1No voltage detected at the water valve relay (steam models only, only appears…View all 43 error codes
FC E1Model/Serial number not programmed.FC E2Model/Serial number not matching between ACU and UIC.FC E3Wi-Fi connection fault.FC E4USB stick failure (USB full, not detected, or not accessible).FC E5Software update failureFC E6Model setup export failureFC E7Model setup import failureFC E8Wi-Fi module not responding or not connected.FP E1Coin 1 circuit error.FP E2Coin 2 circuit error.FP E3Card reader communication error.L2Low L2 voltage (less than 50V) detected at the CCU.pfPower failure occurred while the dryer was running.
Service modes (23)
- Component ActivationFrom Service Diagnostics Diagnostics Home screen, select 'Component Activation'
- Customer-Focused Drying Mode Adjustment1
- Customer-Focused Dryness Level Adjustment1. Turn cycle selector knob to an automatic cycle. 2. From the Automatic Cycle Main Screen, press…
- diagnosticPress DELICATES keypad for one second while in any of the set-up codes 1 through 6 (or while dAS…
- Diagnostic Mode["Enter Setup Mode first.","Press DELICATES keypad for one second while in any of the set-up codes…
- diagnostic_modePress DELICATES keypad for one second while in any of the set-up codes 1 through 6 (or while dAS…
- helpPress HEAVY DUTY keypad while in special pricing option step 2.XX (or while dAS displays if…
- Help Mode["Enter Setup Mode first.","Press HEAVY DUTY keypad while in special pricing option step 2.XX (or…
- help_modePress HEAVY DUTY keypad while in special pricing option step 2.XX (or while dAS displays if…
- model_serial_number_menuEnter Help Mode first
- Model/Serial Number Menu["Enter Help Mode first.","While on the S0 screen press the HEAVY DUTY keypad.","Use NORMAL keypad…
- Quick Diagnostic TestFrom Diagnostics Home screen, select 'Error Diagnostic', then select 'Quick Diagnostic Test'
- Service Diagnostic Mode1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only DONE/COMPLETE…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- setupPD Models
- Setup Mode["COIN Models
- setup_modeCOIN Models
- UI Component TestFrom Diagnostics Home screen, select 'Component Activation', then select 'UI Component Test'
- USB Menu["Enter Help Mode first.","While on the USB screen press the HEAVY DUTY keypad.","Use NORMAL keypad…
- usb_menuEnter Help Mode first
- User Interface/Control System TestAfter activating Service Diagnostic Mode, press and release the 1st button used to activate Service…
- wi-fi_menuFrom the F0 screen in setup mode, press HEAVY DUTY keypad to enter Wi-Fi mode
- wifi_menuWhile in setup mode on the F0 screen, press the HEAVY DUTY keypad to enter Wi-Fi mode.
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass