Model reference
Amana RC10B-PB/P75085-4M
Microwave
3 documents53 error codes16 service modes
Available documentation
Tech Sheet
- Tech Sheet 8563818 Rev A16 pg
Tech Tip
- Instruction Sheet - 8533777 - Rev A8 pg
Quick Reference
- Quick Reference Manual16 pg
MyPros+ Max
Diagnose your Amana RC10B-PB/P75085-4M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (53)
CodeMeaning
AFLow inlet air flow detected at install.E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:50No voltage detected at the water valve relay (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).F1Internal circuit board failure or A/D error(s).F1E0Internal circuit board failure.F1E1A/D error.F1E2A/D error.View all 53 error codes
F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F2Shorted key (keypad short circuit).F2E0Shorted key (keypad short circuit).F2E1User Interface stuck button (depressed for over 20 seconds); only appears in…F2E4UI Software ErrorF2E5UI Software ErrorF3Oven sensor open circuit, oven sensor short circuit, bake/broil…F3E0Oven sensor open circuit.F3E1Oven sensor short circuit.F3E2Bake/broil over-temperature condition.F3E3Clean mode over-temperature condition.F4E1Heater 1 failure or connector problem; no voltage detected at the heater relay.F4E2Heater 2 failure or connector problem (electric models only); no voltage…F4E3Restricted airflow that may affect dryer performance.F4E4L2 line voltage error (less than 50 V detected at the ACU), electric models…F5Door and latch switch mismatch during clean mode.F5E0Door and latch switch mismatch during clean mode.F5E1Door latch not functioning during clean mode.F5E2Door and latch switch mismatch during clean mode.F6E2Communication errorF6E3Communication errorL2Low line voltage (less than 30V) detected at installation.PFPower failure occurred while the dryer was running.
Service modes (16)
- Adjusting Customer-Focused Dryness LevelIn standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
- Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
- Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
- Customer-Focused Drying Mode Adjustment1
- diagnosticPress CANCEL > CANCEL > START within 5 seconds
- Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
- Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
- Diagnostic Test Mode["Ensure the dryer is in standby mode (plugged in and all indicators off).","Within 5 seconds…
- diagnostic_test_modeAfter entering diagnostic mode (CANCEL>CANCEL>START), press the corresponding button to test each…
- Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
- Key Activation & Encoder TestFrom Service Diagnostic Mode, press and release the 1st button used to activate Service Diagnostic…
- Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Clothes…
- Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
- Service Diagnostic Mode1
- Service Test ModeFrom Service Diagnostic Mode, press and release the 2nd button used to activate Service Diagnostic…
- Software Version DisplayFrom Service Diagnostic Mode, press and hold the 2nd button used to activate Service Diagnostic…
Full entry steps, exit procedures, and test sequences are available in Max.