mypros+
Model reference

Amana RCK-1/P75920-1M

Microwave

7 documents68 error codes21 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10251191 - Rev A12 pg
    Covers this model
  • Tech Sheet - W10156038A16 pg
    Covers this model
  • Tech Sheet - W10156040A12 pg
    Covers this model
  • Tech Sheet 8563818 Rev A16 pg
    Covers this model

Service Manual

  • Job Aid - 4322536A (G-20)76 pg
    Covers this model

Tech Tip

  • Instruction Sheet - 85281108 pg
    Covers this model

Installation Guide

  • Instruction Sheet2 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RCK-1/P75920-1M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (68)

CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push To…AFRestricted airflow condition exists.E1Thermistor is open.E2Thermistor has shorted.E3User interface or software mismatchF-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-24Inlet thermistor is open (only appears in diagnostic test mode).F-25Inlet thermistor is shorted (only appears in diagnostic test mode).F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition exists (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.
View all 68 error codes
F:72Console electronics failure.F:73Console electronics failure.F:74Console electronics failure.F:75Console electronics failure.F:76Console electronics failure.F:77Console electronics failure.F:78Console electronics failure.F0E0No error(s) foundF1E0Internal failureF1E1Internal failureF2E0Keypad disconnected.F2E1Stuck key / shorted key.F2E3Keypad hardware failure.F3E0Oven sensor open or shorted.F3E1Not applicable for single oven model.F3E2Warming drawer sensor shorted (oven not equipped with this feature).F3E3Meat probe shorted.F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communication.F6E1Cook oven over temperature.F6E2Clean oven over temperature.F6E4User interface / appliance manager mismatch.F6E5Cavity size is incorrect.F6E6Lost communication between UI and AM1.F8E0Low fan speed underspeed.F8E1Low fan speed overspeed.F8E2High fan speed underspeed.F8E3High fan speed overspeed.L2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.

Service modes (21)

  • Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
  • Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
  • customer_focused_drying_mode_adjustment1
  • Customer-Focused Drying Mode Adjustment1
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["Ensure dryer is in standby mode (plugged in but not powered up).","Press and hold the Dryness…
  • Customer-Focused Dryness Level Adjustment1
  • Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
  • Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
  • Diagnostic Test Mode1
  • diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • Diagnostics Mode["Press three different keys in sequence three times in a row within 8 seconds (example
  • display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
  • Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
  • Factory Test["Ensure door is open.","Set Signal switch to HIGH.","Set Timer to TIMED DRY or AUTO MOISTURE…
  • Install Diagnostics1
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
  • manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Software Version Display1

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass