mypros+
Model reference

Amana RL6-10/P76382-2M

Microwave

8 documents55 error codes26 service modes

Available documentation

Tech Sheet

  • techsheet-3979719.pdf8 pg
    Covers this model
  • Tech Sheet - W10251191 - Rev A12 pg
    Covers this model
  • Tech Sheet - W10156038A16 pg
    Covers this model
  • Tech Sheet - W10156040A12 pg
    Covers this model
  • Tech Sheet 8563818 Rev A16 pg
    Covers this model

Service Manual

  • Job Aid - 4322536A (G-20)76 pg
    Covers this model

Tech Tip

  • Instruction Sheet W11420067 - Rev A1 pg
    Covers this model
  • Instruction Sheet - 85281108 pg
    Covers this model
MyPros+ Max

Diagnose your Amana RL6-10/P76382-2M.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (55)

CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push To…AFRestricted airflow condition exists.E1Thermistor is open.E2Thermistor has shorted.E3User interface keyswitch or software mismatch between console electronics and…F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-24Inlet thermistor is open (only appears in diagnostic test mode).F-25Inlet thermistor is shorted (only appears in diagnostic test mode).F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-30Restricted airflow condition exists (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in Diagnostic Test Mode).F:20No voltage detected at the heater relay (appears ONLY in Diagnostic Test Mode).F:22Outlet thermistor is open.F:23Outlet thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in Diagnostic Test Mode).F:25Inlet thermistor is shorted (appears ONLY in Diagnostic Test Mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in Diagnostic Test Mode).F:29Moisture sensor strip has shorted (appears ONLY in Diagnostic Test Mode).F:30Restricted air flow condition exists (appears ONLY in Diagnostic Test Mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in Diagnostic Test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.
View all 55 error codes

Service modes (26)

  • Console Diagnostics - Switches and Indicators["Enter diagnostic test mode (see above).","Press each button or turn the cycle selector to each…
  • Console Diagnostics (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode as described above.","Press each button or turn the cycle selector…
  • customer_focused_drying_mode_adjustment1
  • Customer-Focused Drying Mode Adjustment1
  • Customer-Focused Drying Mode Adjustment (CF1/CF2/CF3)["Ensure dryer is in standby mode (plugged in but not powered up).","Press and hold the Dryness…
  • Customer-Focused Dryness Level Adjustment1
  • Damp Dry Test["Begin with an empty dryer and clean lint screen.","Set Timer to DAMP DRY.","Set Fabric…
  • Diagnostic - Door Switch["Enter diagnostic test mode.","Open the door
  • Diagnostic - Moisture Sensor["Enter diagnostic test mode.","Locate two metal strips on the face of the lint screen…
  • Diagnostic Test Mode["Ensure the dryer is in Standby Mode (plugged in and all indicators off).","Press the following…
  • diagnostic_test_mode1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • display_line_voltageAfter all saved fault codes have been displayed in diagnostic test mode, press the End of Cycle…
  • Door Switch Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Open the door
  • Dryness Level Adjust (TEST #4a)["Enter the Diagnostic Test Mode (MORE TIME, LESS TIME, MORE TIME, LESS TIME within 5…
  • Dryness Level Adjust Mode["Enter the Diagnostic Test Mode (MORE TIME → LESS TIME → MORE TIME → LESS TIME within 5…
  • Factory Test["Open the dryer door.","Set Fabric Care/Temperature switch to AIR FLUFF.","Set Signal switch to…
  • Install Diagnostics1
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Manual Load Test1. Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
  • manual_load_test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Done…
  • Moisture Sensor Diagnostic (within Diagnostic Test Mode)["Enter the Diagnostic Test Mode.","Locate two metal strips on the face of the lint screen…
  • Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
  • Software Version Display1
  • UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass