Model reference
Amana RR-820
Microwave
4 documents10 error codes4 service modes
Available documentation
Tech Sheet
- Instruction Sheet - TECH SHEET20 pg
- Tech Sheet12 pg
- Tech Sheet8 pg
Service Manual
- TECHNICAL MANUAL JennAir® and KitchenAid® Under-Counter Microwave Oven with Drawer55 pg
MyPros+ Max
Diagnose your Amana RR-820.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (10)
CodeMeaning
-F2-Keyboard (membrane switch) failure.-F3H-Humidity sensor failure.-F3T-Temperature sensor failure.-F7-Power to magnetron interrupted.:Flashing colon indicates a power failure has occurred.ERRORHumidity sensor (AH sensor) cannot balance the bridge circuit due to…F2Touch panel failure.F6Microwave relay failure.NTC OPENHood thermistor is open (displays 'NTC OPEN, CALL FOR SERVICE').NTC SHORTHood thermistor is shorted (displays 'NTC SHORT, CALL FOR SERVICE').Service modes (4)
- AH Sensor Diagnostic Test (Water Load Cooking Test)["Ensure oven has been plugged in at least 2 minutes before testing.","Fill approximately 200 ml…
- Self-Diagnostic / Touch Panel Test Mode["Press and hold CANCEL•OFF while opening the door.","While still holding the CANCEL•OFF button…
- Self-Diagnostic Test Mode["Press and hold the OFF/CANCEL button while opening the door.","While still holding the OFF/CANCEL…
- Self-Diagnostic Test Mode (Touch Panel and Microcomputer Board Test)["Depress the 'Cancel OFF' button while opening the door.","While still depressing the 'Cancel OFF'…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana microwave models
76,000+ service documents · 19,000+ error codes · 100+ brands