Model reference
Amana RCC-4-L1/P73409-1M
Oven
4 documents37 error codes10 service modes
Available documentation
Tech Sheet
- Tech Sheet24 pg
Tech Tip
- Instruction Sheet - 397971412 pg
Installation Guide
- Installation Instructions7 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Amana RCC-4-L1/P73409-1M.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (37)
CodeMeaning
CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…ErProcessor reset error; the control failed to save cycle information during a…F0E0No error(s) foundF1E0Internal failureF1E1Oven appliance manager failure (not applicable for lower oven on double oven…F2E0Keypad disconnected.F2E1Stuck key or shorted key.F2E2LED error on user interface.F3E1Lower oven temperature sensor open or shorted.F3E2Warming drawer sensor shorted (oven not equipped with this feature).F3E3Meat probe sensor shorted.F4E1Convection thermistor fault (microwave oven sensor).F4E2Internal temperature sensor fault (microwave oven sensor).F4E4Humidity sensor fault (microwave oven sensor).F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communications between user interface and appliance manager.F6E1Cook oven over temperature.F6E2Clean oven over temperature.F6E3Mini oven/warm drawer over temperature (not for built-in ovens).F6E4User interface/appliance manager mismatch.F6E5Cavity size is incorrect.F7E0Water level is not high enough or water did not boil fast enough.F7E4Conductivity sensor not connected.F8E0Low fan speed underspeedF8E1Low fan speed overspeedF8E2High fan speed underspeedF8E3High fan speed overspeedView all 37 error codes
LdLong drain; it takes longer than 5 minutes to pump out water to the point where…LFLong fill; the water fill time exceeded 10 minutes, causing the water valves to…LSLid switch error; the control cannot detect lid switch opening/closing…obOff balance; the motor controller detected an unrecoverable off-balance…PFPower failure detected during a running cycle; the washer lost power mid-cycle.SLSuds lock; excessive suds detected and the unit was unable to clean out suds…SrStuck relay; the relay has failed in the closed position so the machine…
Service modes (10)
- Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- Diagnostic modePress OFF, OFF, START to enter diagnostic mode and check fault codes.
- Diagnostics ModePress any 3 keys 3 times within 8 seconds
- Extended diagnostic mode (relay activation and testing)1
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
- Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
- User interface programming (after UI replacement)1
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana oven models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax