Tech Sheet
- Fiche technique - Tech Sheet W103844608 pg
- Tech Sheet - W10384454 - Rev A8 pg
- Tech Sheet - W10434980 - Rev A (FR)8 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Service Flash
- Technical Service Pointer - W10412840 (Passive Door Hinge Design)6 pg
- Technical Service Pointer - W10473748 (F9 E0 Error Code)6 pg
MyPros+ Max
Diagnose your Amana AER5844VCB2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (25)
CodeMeaning
F1Internal circuit board failure or A/D error(s)F1 E*Control board failure (all F1 sub-codes indicate control fault).F1E0Internal circuit board failure (LCC 180/190 display).F1E1Internal circuit board failureF1E2Internal circuit board failureF2Shorted key on control panel (LCC 90/95 display).F2E0Shorted key on control panel (LCC 180/190 display).F3Oven sensor open circuit, oven sensor short circuit, bake/broil excessive…F3 E0Oven temperature sensor fault (open or shorted)F3 E1Lower oven temperature sensor fault (MRC II double oven models).F3 E2Warming drawer temperature sensor fault.F3E0Oven sensor open circuit (LCC 180/190 display).F3E1Oven sensor short circuit (LCC 180/190 display).F3E2Bake/Broil excessive temperature (LCC 180/190 display).F3E3Clean mode excessive temperature (LCC 180/190 display).F5Door and switch mismatch during clean mode, or door latch not functioning…F5 E0Door position switch faultF5 E1Door latch switch/system faultF5 E2Door switch fault.F5E0Door and switch mismatch during clean mode (LCC 180/190 display).F5E1Door latch not functioning during clean mode (LCC 180/190 display).F5E2Door and switch mismatch during clean mode (LCC 180/190 display).F6 E*Control communication failure.F9Defective housing wiring or defective range wiring (LCC 90/95 display).F9E0Defective housing wiring or defective range wiring (LCC 180/190 display).Service modes (11)
- diagnosticPress CANCEL > CANCEL > START within 5 seconds.
- diagnostic_test_modeWhile in diagnostic mode, press the following buttons to test individual relays
- Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press individual keypads to test control relays
- LCC Diagnostic Mode (LCC90/LCC95/LCC180)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- LCC190 Diagnostic Mode (Self Clean, Convection models)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME or TEMP/HOUR '+' key to cycle through…
- MRC Diagnostic Mode["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC Diagnostic Mode (Fan/True Convection Electric - Oven Light entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' key to cycle through diagnostic…
- MRC II Diagnostic Mode (Number 3 key entry - KitchenAid models)["Press OFF/OFF/START or CANCEL/CANCEL/START in sequence.","Press the number '3' key to cycle…
- MRC II Diagnostic Mode (TEMP/TIME entry)["Press CANCEL, CANCEL, START in sequence.","Press TEMP/TIME '+' keypad to cycle through diagnostic…
- Temperature Adjustment ModeStep 1