Model reference
Amana AKM-1B-P85549-3S
Range
3 documents51 error codes28 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10436012 - Rev A16 pg
- Tech Sheet - W1047033212 pg
Tech Tip
- Instruction Sheet - 397971412 pg
MyPros+ Max
Diagnose your Amana AKM-1B-P85549-3S.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (51)
CodeMeaning
3 beepsThermistor or wire harness is either shorted or open, detected when Push To…d13Coin 2 errord16Generation 2 debit card reader errord5Coin 1 errord9Low voltage detection errorF0 E5Off balance load detected during cycle operation.F01CCU (Central Control Unit) errorF03Main control detects an out of range pressure signal from the pressure…F07Main control cannot determine position of shifter (shifter system failure).F1 E1Main control faultF1 E6Control board recognized line voltage below 90 VAC.F11MCU (Motor Control Unit) has a failure, possibly due to a repeating under or…F2 E1Washer keypad stuck errorF20No water detected entering washerF21Long drainF22Door lock errorF24Temperature sensor errorF25Tachometer errorF26Door switch errorF27Overflow conditionF28Communication failure between CCU and MCU.F29Door unlock errorF3 E2Pressure sensor faultF3 E3Inlet water temperature faultF31Overheating of motorF32No fill condition detected; water level does not change.F33Pump disconnectedF34Load detected in washer during Washer Cleanout Cycle.F5 E1Lid switch faultF5 E3Lid switch faultView all 51 error codes
F5 E4Lid unlock faultF7 E1Basket speed sensor faultF7 E2Motor control faultF7 E5Shifter faultF70Communication failure between CCU and UI (User Interface).F71Communication failure between CCU and UI; electrical connection is damaged.F73Communication error within the User Interface, possibly caused by a power…F74Communication error within the User Interface (same as F73).F77Off balance load detected.F8 E1No fillF8 E3Overflow conditionF9 E1Long drainFC E1Model/serial number not programmedFC E2Model/serial numbers do not match between the Main Control and User Interface…FC E4USB faultFC E5Software update failureFC E6Model setup export failureFC E7Model setup import failureFP E1Coin 1 circuit errorFP E2Coin 2 circuit errorFP E3Card reader communication error.
Service modes (28)
- Code Display Mode["PD Models
- Cycle Credit["Enter Washer Diagnostic Mode (entire display flashing).","Press the PERM
- Damp Dry Test["Begin with an empty dryer and clean lint screen.","Set Timer to DAMP DRY.","Set Fabric…
- diagnosticNo diagnostic operation mode or temperature adjustment mode exists for the JED4536 series downdraft…
- Factory Test["Open the dryer door.","Set Fabric Care/Temperature switch to AIR FLUFF.","Set Signal switch to…
- Flashing Mode["PD Models
- Help Mode["First enter Service Mode.","Use the NORMAL keypad to advance to program location 2.xx (Special…
- Help Mode (dAS Mode)["Open the service door or insert a manual diagnostic card.","The message dAS will appear in the…
- Help Mode (PD Models)["Open the service door.","Press the WOOLENS button until the display reads 2.XX.","Press the PERM
- Manual Overview Test Cycle["Enter Washer Diagnostic Mode (entire display flashing).","Press the WHITES button to start the…
- P-01 Clear Errors["Enter Service Diagnostic Test Modes.","Display shows P-01.","Press START to clear an active error…
- P-02 Cycle Credit["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-02 is displayed.","Press START…
- P-03 Service Diagnostic["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-03 is displayed.","Press START…
- P-04 Manual Diagnostic["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-04 is displayed.","Press START…
- P-05 Calibration Cycle["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-05 is displayed.","Press START…
- P-07 UI Diagnostics["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-07 is displayed.","Press START…
- P-09 Tachometer Verification["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-09 is displayed.","Press START…
- P-12 Clean Washer Cycle["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-12 is displayed.","Press START…
- Quick Overview Test Cycle["Enter Washer Diagnostic Mode (entire display flashing).","Press the WOOLENS button to start the…
- Quick Spin Cycle["Enter Washer Diagnostic Mode (entire display flashing).","Press the COLORS button to start the…
- Service Access Code (No Console Removal)["Only functions on washers set up for 0 vend price without any Special Pricing set-up, and…
- Service Diagnostic Test Modes (Entry)["1. For coin models
- Service Diagnostic Test Modes (main entry)["For coin (PD) models
- Set-Up Mode (PD Models)["Insert service access door key, turn, and lift to remove service access door."]
- Set-Up Mode (PR Models)["Install debit card reader per manufacturer's instructions.","Insert a set-up card (supplied by…
- Technician Service Access Code (PR models, free vend only)["Press the POWERWASH, EXTRA RINSE, TEMPERATURE, and DELICATES key pads within 10 seconds."]
- Washer Cleanout Cycle["Enter Washer Diagnostic Mode (entire display flashing).","Press the BRIGHTS button to start the…
- Washer Diagnostic Mode["First enter 'Start Operating Set-Up' (set-up mode).","Press and hold the DELICATES AND KNITS…
Full entry steps, exit procedures, and test sequences are available in Max.