Error codes (38)
CodeMeaning
1-1Control detected K1 pilot relay stuck closed.1-2Control software issue10-1Dispenser electrical problem10-3Drying fan error2-1Control detected stuck key(s) in keypad or keypad connection.2-2Shorted key or short circuit(s) in keypad or in control's input lines that read…3-1Open connector or component in Temperature Sensing circuit, open or faulty…3-2Shorted connection or component in Temperature Sensing circuit, shorted or…3-3OWI failed calibration, or drain hose check valve not sealing allowing dirty…4-3Wash motor not running5-1Door stuck open5-2Door stuck closed6-1Low or no water (mechanical problem)6-2Fill valve electrical problem6-3Suds or air in pump6-4Float switch open6-6Cool water6-7Flowmeter problem6-8Regeneration valve electrical problem (water softener models).7-1No heat7-2Heater stuck on8-1Slow drain8-2Drain motor electrical problem8-3Drain stuck on9-1Diverter problem (function 9, problem 1).9-2Diverter problem (function 9, problem 2).9-3Diverter disk missing from sump.ADD GROUND COFFEEThe ground coffee function has been selected without placing any ground coffee…CLOSE DOOR!The service door is open.DESCALE!The flowmeter has measured water volume exceeding the set limit for the…View all 38 error codes
FILL BEANS CONTAINER!Coffee beans have run out or clutch is obstructed by stones or foreign objects…FILL TANK!Water tank is empty, incorrectly positioned, float is stuck, or reed sensor is…GENERAL ALARMInternal fault detectedGROUND TOO FINE ADJUST MILLWater is running off too slowly due to fine grind, removed water tank, or air…INSERT BREWING UNITThe brewing unit has not been replaced after cleaning.INSERT GROUNDS CONTAINERAfter cleaning, the grounds container has not been replaced.INSERT MILK CONTAINER!The milk container is missing or incorrectly positioned.INSERT WATER SPOUT Press OKThe hot water spout is not installed or detected.
Service modes (11)
- Cycle Advance (Cycle Operation Viewer)Press and hold Cycle Select for 5 seconds
- Cycle Interval Advance (Cycle Operation Debug)Press and hold Cycle Select for 5 seconds
- cycle_step_throughPress and hold the Cycle Select button for 5 seconds
- diagnosticIn standby mode, press any 3 keys in sequence 1-2-3-1-2-3-1-2-3 with less than one second between…
- Display Test Mode["With the coffee system in standby (plugged in with the main switch on but the machine off), open…
- Load Test Mode["With the coffee system in standby (plugged in with the main switch on but the machine off), open…
- Rapid Advance ModePress HI TEMP
- Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
- Reset Upper Position of Infuser["With the machine in standby (plugged in with the main switch on, but machine off), open the…
- Service Diagnostics - Error Code ReadingAfter entering Service Diagnostics Cycle
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…
Full entry steps, exit procedures, and test sequences are available in Max.