mypros+
Model reference

Amana SP19W-P73320-10W

Refrigerator

1 document33 error codes16 service modes

Available documentation

Tech Sheet

  • Tech Sheet - 160217244 pg
    Covers this model
MyPros+ Max

Diagnose your Amana SP19W-P73320-10W.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (33)

CodeMeaning
00No faults present.1-1Control detected K2 pilot relay stuck closed.1-2Control software issue; all LEDs are on due to software or hardware…10-1Dispenser electrical problem; loose connection in dispenser circuit and/or open…10-3Drying fan error; loose connection in fan circuit and/or open fan motor.2-1Control detected stuck key(s) in keypad or keypad connection.2-2User interface cannot communicate with main control; loose user interface…3-1Open connector or component in Temperature Sensing circuit (open or faulty…3-2Shorted connection or component in Temperature Sensing circuit, or incoming…3-3OWI (Optical Water Indicator) failed calibration.4-3Wash motor not running due to loose connection in motor circuit and/or faulty…5-1Door switch stuck open; loose connection in door switch circuit and/or door…5-2Door switch stuck closed; control detected door switch did not open between…6-1Low or no water reaching dishwasher (mechanical problem).6-2Fill valve electrical problem; loose connection in fill valve circuit and/or…6-3Suds or air detected in pump.6-4Overfill float switch stuck in overfill position and/or dishwasher not level.6-6Incoming water too cool (under 84°F / 29°C).6-7Flowmeter disconnected or damaged.6-8Water softener regeneration valve electrical problem (loose connection in regen…7-1No heat; control disabled heater due to detected water heating problem.7-2Heater stuck on; heater drive circuit on the control failed.8-1Slow drain due to obstructed drain hose or path.8-2Drain motor electrical problem; loose connection in drain motor circuit and/or…8-3Drain motor stuck on; drain motor drive circuit on the control failed.CdCondenser Fan Output fault.CLCommunication Link Lost between boards.CPCompressor Output fault.dHDefrost Heater Output fault.dPDamper Motor Output fault.
View all 33 error codes

Service modes (16)

  • Customer Cycle Rapid Advance["Start a customer cycle.","Press HIGH TEMP
  • Force/Terminate DefrostToggle freezer door light switch 5 times within 6 seconds.
  • Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
  • Service Diagnostics Cycle1
  • Service Mode (Mode A – System Checks and Mode B – Calibration)1
  • Service Mode A - Option 1: Display Error CodesWhile in Service Mode A, press the Confirm Settings Key to enter this option.
  • Service Mode A - Option 10: Display Door Opening CountWhile in Service Mode A, navigate to Option 10 and press the Confirm Settings Key.
  • Service Mode A - Option 11: Display Defrost Terminator StatusWhile in Service Mode A, navigate to Option 11 and press the Confirm Settings Key.
  • Service Mode A - Option 2: Display Average On and Off TimesWhile in Service Mode A, navigate to Option 2 and press the Confirm Settings Key.
  • Service Mode A - Option 3: Forced Pull-downWhile in Service Mode A, navigate to Option 3 and press the Confirm Settings Key.
  • Service Mode A - Option 4: Independent Evaporator Fan ModeWhile in Service Mode A, navigate to Option 4 and press the Confirm Settings Key.
  • Service Mode A - Option 5: Display Current Actual TemperaturesWhile in Service Mode A, navigate to Option 5 and press the Confirm Settings Key.
  • Service Mode A - Option 6: Force Compressor On OnlyWhile in Service Mode A, navigate to Option 6 and press the Confirm Settings Key.
  • Service Mode A - Option 7: Force Condenser Fan On OnlyWhile in Service Mode A, navigate to Option 7 and press the Confirm Settings Key.
  • Service Mode A - Option 8: Force Evaporator Fan On OnlyWhile in Service Mode A, navigate to Option 8 and press the Confirm Settings Key.
  • Service Mode A - Option 9: Force Motorized Damper On OnlyWhile in Service Mode A, navigate to Option 9 and press the Confirm Settings Key.

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass