Error codes (57)
CodeMeaning
1-1Control detected K2 pilot relay stuck closed.1-2Damaged or corrupted memory on control board, or incompatible software…10-1Dispenser electrical problem10-3Drying fan error2-1Control detected stuck key(s) in keypad or keypad connection.2-2User interface cannot communicate with main control3-1Open connector or component in Temperature Sensing circuit; open or faulty…3-2Incoming water temperature above 167°F (75°C), or shorted connection/component…3-3OWI calibration failure4-3Wash motor not running due to loose connection in Motor circuit and/or faulty…5-1Door stuck open5-2Door stuck closed6-1Low/no water6-2Fill valve electrical problem6-3Suds or air in pump6-4Float switch open6-6Incoming water under 84°F (29°C)6-7Disconnected or damaged flowmeter.6-8Regen valve electrical problem7-1No heat7-1 (flowmeter)Disconnected or damaged flowmeter.7-2Heater stuck on8-1Slow drain8-2Drain motor electrical problem8-3Drain stuck on8-5Drain stuck on9-1Diverter can't find position9-2Diverter stuck on9-3Diverter disk missing9-4Lower spray arm errorView all 57 error codes
F10E1Dispenser electrical problemF10E3Drying fan errorF1E1Control detected K2 pilot relay stuck closed.F1E2Damaged or corrupted memory on control board, or incompatible software…F2E1Control detected stuck key(s) in keypad or keypad connection.F2E2User interface cannot communicate with main control due to loose user interface…F3E1Open connector or component in Temperature Sensing circuit, open or faulty…F3E2Shorted connection or component in Temperature Sensing circuit, shorted or…F3E3OWI failed calibration due to OWI failure or drain hose check valve not sealing.F4E3Wash motor not running due to loose connection in motor circuit and/or faulty…F5E1Door stuck openF5E2Door stuck closedF6E1Low or no water (mechanical problem)F6E2Fill valve electrical problemF6E3Suds or air in pumpF6E4Float switch openF6E7Disconnected or damaged flowmeter.F6E8Regen valve electrical problemF7E1No heatF7E2Heater stuck onF8E1Slow drainF8E2Drain motor electrical problemF8E3Drain motor stuck onF9E1Diverter can't find positionF9E2Diverter stuck onF9E3Diverter disk missingF9E4Lower spray arm error
Service modes (10)
- Clear Customer Error HistoryDuring Service Diagnostics Cycle interval where Hi Temp LED is on (interval 22), press Hi Temp key…
- Customer Cycle Rapid Advance["Start a customer cycle.","Press HIGH TEMP
- Error Code ReadingPress any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second between key presses
- Rapid Advance (Customer Cycle)After starting a customer cycle, press HI TEMP
- Rapid Advance (Customer Cycles)After starting a customer cycle, press HIGH TEMP
- Rapid Advance ModePress HI TEMP
- Rapid Advance Mode (Customer Cycles)After starting a customer cycle, press HIGH TEMP
- Sales Demo Mode ExitRun Service Diagnostics Cycle to clear Demo mode.
- Service Diagnostics - Error Code ReadingAfter entering Service Diagnostics Cycle
- Service Diagnostics CycleWhile in standby, press any 3 keys in the sequence 1-2-3-1-2-3-1-2-3 with no more than 1 second…