Model reference
Amana SR22W-P73320-20W
Refrigerator
20 documents29 error codes31 service modes
Available documentation
Tech Sheet
- Tech Sheet - W102793422 pg
- Service Specifications - Side-by-Side Refrigerator Technical Information4 pg
- Tech Sheet - 82083408 pg
- Tech Sheet - W102388502 pg
- techsheet-w10279330.pdf2 pg
- Tech Sheet - 12893042 - Wiring Diagram Technical Information Side by Side Refrigerator2 pg
- Whirlpool Refrigerator KFCS22EVMS00 Tech Sheet 128279642 pg
- Tech Sheet - 12827964.pdf2 pg
- Tech Sheet - W10465888 - Rev A2 pg
- Fiche technique - Tech Sheet W10738569 - Rev B2 pg
- Tech Sheet - W102388432 pg
- Bottom Mount Refrigerator---Technical Information2 pg
- Bottom Mount Refrigerator - Technical Information2 pg
- Tech Sheet2 pg
- Tech Sheet - KFIS29PBMS022 pg
- Tech Sheet - W102553162 pg
Service Manual
- DEFROST SYSTEMS Training Manual94 pg
Training
- Defrost Systems94 pg
- Job Aid - Defrost Systems R-10794 pg
Installation Guide
- Installation Instructions32 pg
MyPros+ Max
Diagnose your Amana SR22W-P73320-20W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (29)
CodeMeaning
E0No errors present in the ice maker.E1Ice maker errorE2Ice maker errorE3Ice maker errorE4Ice maker errorE5Ice maker errorE6Manufacturing codeErManufacturing codeF1E0Oven user interface failure.F1E1Internal oven appliance manager error.F2E0Keypad disconnected.F2E1Stuck/shorted key.F3E0Main oven sensor open or shorted.F3E1Bottom oven sensor open or shorted.F3E3Meat probe connector jack or meat probe shorted.F5E0Door and latch switch do not agree (main/upper oven).F5E1Latch not operating (main/upper oven).F5E3Door and latch switch do not agree (lower oven).F5E4Latch not operating (lower oven).F6E0Oven user interfaceF6E1Over temperature (main/upper oven).F6E3Over temperature (lower oven).F6E4User Interface / Appliance Manager state status mismatch.F6E6Oven appliance managerF6E9Oven appliance managerF6EAUser Interface over temperature condition detected by NTC sensor on UI circuit…F9E0Product not wired correctly.OPOpen thermistor detected during service test (thermistor circuit is open).SHShorted thermistor detected during service test (thermistor circuit is shorted).Service modes (31)
- 2001 K Model Counter Depth SxS (KSBP25/KSBS25/KSCS25/KSFS25) - Diagnostics Mode["Ensure control is turned on and in normal cooling mode","Press and hold the Water Filter Reset…
- ADC 12566102 (SxS) / 12566101 (Bottom Mounts) - Forced Defrost["Toggle freezer door light switch 5 times within 6 seconds"]
- Amana 48 inch Built-in SxS - Electronic Testing Forced Compressor Start["Press Display On pad to activate control panel","Simultaneously press and hold Max Frz and…
- Amana 48 inch Built-in SxS - Electronic Testing Forced Defrost["Press Display On pad to activate control panel","Simultaneously press and hold Max Ref and…
- Amana 48 inch Built-in SxS - Program Mode["Open refrigerator door","Press Display On pad","Press * pad","Press the following sequence within…
- Amana 84 inch Bottom Mount - Program Mode["Open refrigerator door","Press Display On pad","Press * pad","Press the following sequence within…
- Amana Top Mount (Frigidaire-built) - System Diagnostics Forced Defrost["Press the refrigerator light switch five times in a six second time period"]
- Amana/Galesburg Platform After April/June 2003 (12002104) - Forced Defrost["Cycle cold control on and off three times in six seconds","Leave cold control in closed (call for…
- Diagnostics ModeSingle Ovens
- Forced Defrost Mode["1
- Galesburg Platform Before May 2003 (61005988) - Forced Defrost["Jump L1 to Test terminal on ADC board"]
- Jazz Control - Forced Defrost Mode["Hold the refrigerator door light switch closed","Press the Refrigerator Temperature Down keypad 3…
- Jazz Control - Programming Mode["Open the Fresh Food door","Hold the Fresh Food door light switch closed","Press the Freezer…
- Jazz Control - Service Test Mode["Hold the refrigerator door light switch closed","Press the Refrigerator Temperature Up keypad 3…
- Jenn-Air Luxury Series - Diagnostic Control Mode["With fresh food door open and fresh food door switch in closed position","Press Power Interrupt 3…
- Legacy Amana/Maytag/Jenn-Air - Forced Defrost["Compressor must be running and one compartment door closed","Press either door light switch 4…
- Model GAFZ21XXMK00 - ADC Test Method #1["Turn the thermostat off for 15 seconds","Turn the thermostat on for 5 seconds","Turn the…
- Model GAFZ21XXMK00 - ADC Test Method #2["Disconnect the refrigerator/freezer from the wall outlet for at least 30 seconds","Turn the…
- Programming Mode["1
- Service Diagnostics ModePress SW1 and SW2 simultaneously for 3 seconds
- Service ModeWithin 60 seconds of connecting power to the product, touch the key sequence ON/OFF, ON/OFF, + for…
- Service Test Mode["1
- Utah Control - Forced Defrost Mode["Press and hold the Door Alarm key (first) and Temperature Down keypad","Release the Door Alarm…
- Utah Control - Programming Mode["Press and hold Door Alarm key","Press Freezer Temperature Down key","PE will appear in the…
- Utah Control - Service Mode["Press and hold Door Alarm key (first) and Refrigerator UP keypad","Release the Door Alarm keypad…
- V Series SxS - Electronic Testing Mode - Forced Compressor Start["Press * pad to activate control panel","Simultaneously press and hold Fast Freeze and Display Off…
- V Series SxS - Electronic Testing Mode - Forced Defrost Start["Press * pad to activate control panel","Simultaneously press and hold Max Cool and Display Off…
- V Series SxS - Program Mode A (Thermistor Temperatures)["Open refrigerator door","Press * pad","Press Vacation pad","Press the following sequence within 6…
- V Series SxS - Program Mode B (Electronic Testing)["Enter Program Mode A first","Press * pad to toggle to Program Mode B","Clean condenser indicator…
- Whirlpool ADC Test Method #1 - Forced Defrost["Turn thermostat off for 15 seconds","Turn thermostat on for 5 seconds","Turn thermostat off for…
- Whirlpool ADC Test Method #2 - Forced Defrost["Unplug unit from wall outlet for 30 seconds","Turn thermostat off","Plug in unit"]
Full entry steps, exit procedures, and test sequences are available in Max.