Model reference
Amana SR25E-P74100-4W
Refrigerator
6 documents62 error codes24 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10221852 - Rev A (FR)6 pg
- Tech Sheet - W10221845 - Rev A6 pg
- Tech Sheet - W10116294A6 pg
- Wiring Diagram - W11263829 - Rev A3 pg
- Wiring Diagram - W11263829 - Rev B2 pg
Installation Guide
- Installation Instructions24 pg
MyPros+ Max
Diagnose your Amana SR25E-P74100-4W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (62)
CodeMeaning
E0-F1EEPROM communications failure, typically caused by power line noise or…E0-F2EEPROM checksum failure, typically caused by power line noise or lightning.E0-F3Key contact closed for more than 60 secondsE0-F5Clean temperature out of range (too high)E1-F1EEPROM communications failure, typically caused by power line noise or…E1-F2EEPROM checksum failure, typically caused by power line noise or lightning.E1-F3Break in oven sensor circuit (open sensor, loosened or disconnected sensor…E1-F5Door switch open during clean cycleE2-F3Short in oven sensor circuit (short in sensor, sensor shorted to casing…E3-F3BAKE/BROIL temperature out of range (too high)F0Default F codeF0 E0No error(s) found (Good).F1Electronic control malfunction.F1 E0EEPROM checksum failure.F1 E1EEPROM communications error.F1 E2UL A/D error(s).F1-E0EEPROM communication error.F1-E1Keypad keytail not connected.F1-E2UL A/D error(s).F1-E5Sensor out of range.F1-E6CANCEL key drive line open.F1-E7PCB thermistor open or shorted.F1E0Internal control board failure.F1E1Internal control board failure.F1E2A/D error(s)F2Shorted key on the control panel.F2 E0Shorted key detected.F2 E1Keytail unplugged.F2 E2A/D Error(s).F2-E0Keypad disconnected.View all 62 error codes
F2-E1Stuck key.F2-E2Cancel key error.F2-E3Oven temp too highF2E0Shorted key (keypad short circuit).F3Oven sensor opened, oven sensor shorted, BAKE/BROIL range over temperature, or…F3 E0Oven sensor opened.F3 E1Oven sensor shorted.F3 E2BAKE/BROIL range over temperature.F3 E3CLEAN range over temperature.F3-E0Main oven sensor open or shorted.F3-E1Self-clean latch will not lock/unlock.F3-E2Warming drawer sensor open or shorted.F3-E3CLEAN range over temperature condition.F3E0Oven sensorF3E1Oven sensorF3E2BAKE/BROILF3E3CLEANF5Door latch or switch system failure (related to latch assembly, motor, door…F5 E0Door and switches do not agree.F5 E1Door latch not operating.F5 E2Latch error during CLEAN.F5-E0Door and switches do not agree (Clean mode).F5-E1Door latch not operating (Clean mode).F5-E2Latch error during CLEAN cycle.F5E0Door and switch mismatch (clean mode).F5E1Door latch not functioning (clean mode).F5E2Door and switch mismatch (clean mode).F6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature (warming drawer).F9Miswired house or miswired range.F9E0Miswired house or miswired cooker power supply.
Service modes (24)
- Bake Temperature Offset AdjustmentPress BAKE pad for 5 seconds
- diagnosticWith the oven not in bake, broil or clean mode, press CANCEL/OFF > CANCEL/OFF > START
- Diagnostics ModeWith oven not in cooking, broiling, or cleaning mode, press Cancel/OFF, Cancel/OFF, START. The…
- Diagnostics Mode (3-digit LCC 90 and LCC 95 Control Display)Press CANCEL 2 times and then START within a 5-second period.
- Diagnostics Mode (Auto Test)1
- Diagnostics Test Mode (All LCC Controls)Press CANCEL 2 times and then START within a 5-second period. Then use individual key presses to…
- Diagnostics Test Mode (Relay Checks)After entering Diagnostics Mode (CANCEL>CANCEL>START), press individual keys to test relays
- DISPLAYPress CANCEL > CANCEL > START to enter Service Mode
- ENG MODEPress CANCEL > CANCEL > START to enter Service Mode
- Fahrenheit to Celsius ConversionPress the BROIL pad for 5 seconds
- FAULTSPress CANCEL > CANCEL > START to enter Service Mode
- Last Fault Code RetrievalPress and hold CANCEL/OFF key for 5 seconds to display the last error code.
- Manual Diagnostics Mode 1 (Full - within 120 seconds of power up)Within 120 seconds of power-up, press Cancel/OFF, Cancel/OFF, then Start
- Manual Diagnostics Mode 2 (Limited - after 120 seconds of power up)After 120 seconds of power-up, press Cancel/OFF, Cancel/OFF, then Start
- Programming Cavity SizeWithin 60 seconds of power up, press the following touchpads in order
- Temperature Adjustment1
- Temperature Adjustment (All LCC Controls)Step 1
- Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
- Temperature Adjustment ModePress and hold BAKE key for 5 seconds
- TEST MODEPress CANCEL > CANCEL > START to enter Service Mode
- Test Mode / Diagnostic ModeWithin 60 seconds of power up, simultaneously hold down the BAKE and CLOCK keys for 5 seconds. The…
- TEST ON (Relay Checks)Press CANCEL > CANCEL > START to enter Service Mode. Upon entry, 'TEST ON' is displayed. Press the…
- USAGEPress CANCEL > CANCEL > START to enter Service Mode
- VERSIONPress CANCEL > CANCEL > START to enter Service Mode
Full entry steps, exit procedures, and test sequences are available in Max.
Related Amana refrigerator models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass