Model reference
Amana TM20F-P75288-4W
Refrigerator
2 documents46 error codes20 service modes
Available documentation
Service Manual
- Service Manual - R020751640 pg
- Service Manual - R020761446 pg
MyPros+ Max
Diagnose your Amana TM20F-P75288-4W.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (46)
CodeMeaning
F0 E0No error(s) found.F1EEPROM checksum failure or UL A/D error(s).F1 E0EEPROM communication error.F1 E1EEPROM checksum failure.F1 E2Lower RTD uncalibrated (internal error).F1 E5Sensor usage out of range (internal error).F1 E7PCB thermistor/sensor open or shorted.F1 E9WIDE Queue full.F1-E1Upper RTD uncalibrated (internal error).F1-E2Lower RTD uncalibrated (internal error).F1-E9WIDE queue full.F1E0Internal board failure.F1E1Internal board failure.F1E2Internal board failure.F2EEPROM communications error or shorted key detected.F2 E0Keypad disconnected.F2 E1Stuck key detected.F2 E2Stuck key detected.F2E0Shorted key.F3Oven sensor opened, oven sensor shorted, BAKE/BROIL range over temperature, or…F3 E0Main oven temperature sensor open or shorted (upper oven).F3 E1Oven sensor shorted.F3 E2BAKE/BROIL range over temperature.F3 E3CLEAN range over temperature.F3-E1Main oven temperature sensor open or shorted (lower oven).F3E0Oven sensor opened.F3E1Oven sensor shorted.F3E2Bake/Broil range over temperature.F3E3Clean range over temperature.F5Door and switches do not agree, door latch not operating, or latch error during…View all 46 error codes
F5 E0Door and switches do not agree (Clean mode)F5 E1Door latch not operating (Clean mode)F5-E0Door and latch switches do not agree during Clean mode.F5-E1Door latch not operating during Clean mode.F5E0Door and switches do not agree (clean mode).F5E1Door latch not operating (clean mode).F5E2Door and switches do not agree (clean mode).F6 E0Lost wide (wired) communicationF6 E1Over temperature condition during cook mode (runaway temp).F6 E2Over temperature condition during clean mode (runaway temp).F6 E3Over temperature condition in warming drawer (runaway temp).F6-E0Lost communications between control boards.F6-E2Over temperature condition during clean mode (runaway temp).F9Miswired house or miswired range (F9E0 on LCC 180/190).F9-E0Product is mis-wired.F9E0Miswired house or miswired range.
Service modes (20)
- Auto Test1
- Clear Fault Codes["Enter Diagnostic Mode by pressing CANCEL > CANCEL > START within 5 seconds.","Press TEMP/TIME '+'…
- Control Reset1
- Diagnostic Mode1. Plug in oven or connect power. 2. Press CANCEL > CANCEL > START within 5 seconds to enter…
- Diagnostics ModeWith the oven not in cooking, broiling, or cleaning mode, press CANCEL/OFF, then CANCEL/OFF, then…
- Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press the following keypads to test individual control relays
- Display Test1
- Fault Code Viewing and Clearing1
- Faults (Error Code Review/Clear)1
- Last fault code recallPress and hold CANCEL/OFF key for 5 seconds to display last error code.
- Semi Automatic Test1
- Temperature Adjustment1
- Temperature Adjustment (Bake Offset)Press and hold BAKE key for 5 seconds
- Temperature Adjustment (Calibration)Press and hold BAKE pad for 5 seconds
- Temperature Adjustment ModePress and hold BAKE key for 5 seconds
- Temperature Calibration1
- Test Mode1
- Test mode (diagnostic)Within 60 seconds of power up, simultaneously hold down the BAKE and CLOCK keys for 5 seconds. The…
- Usage1
- Version1