Model reference

American Dryer AD-200

Dryer

7 documents34 error codes8 service modes

Available documentation

Service Manual

  • AD-200 Service Manual with Tilt Options107 pg
    Covers this model
  • AD-200 Service Manual with Non-Tilt Options82 pg
    Covers this model
  • ADC AD-200 ServiceManual-NonTilt-PH7 OPL106 pg
    Covers this model
  • ADC AD-200 PartsManual-NonTilt-1992-thru-1997-24VAC-PH5 PastProduction OPL76 pg
    Covers this model
  • ADC AD-200 ServiceManual-Tilt PastProduction OPL107 pg
    Covers this model
  • ADC AD-230 Service Manual52 pg
    Covers this model
  • ADC AD-200 ServiceManual-NonTilt-1993-thru-1998 PastProduction OPL82 pg
    Covers this model
MyPros+ Max

Diagnose your American Dryer AD-200.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (34)

CodeMeaning
BAD PROBEIndicates the temperature probe is open or shorted.CALL FOR SERVICEIndicates an I/O board failure.CHECK CONTROL POWERIndicates control power is off.donEDrying and cooling cycles are complete.doorOpen circuit fault in the microprocessor controller's DC door switch circuit…DRY ENABLE FAULTIndicates the dryer is not level and/or all doors are not closed; not ready to…dsflDryer sensor circuit failureEXHAUST HI-LIMIT FAULTIndicates the 225°F (107°C) exhaust temperature disk has opened.EXHAUST HIGH TEMP FAULTIndicates the temperature in the basket (tumbler) exhaust has exceeded 225°F…FAN CONTACTOR FAULTThe fan contactor was not pulled in.FAN OVERLOAD FAULTIndicates the fan (blower) motor overload has tripped open.FILLNo cycle in progress.FRONT BURNER HI-LIMIT FAULTIndicates the 330°F (166°C) temperature disk in the front burner has opened.FRONT BURNER IGNITION CONTROL FAULTFront DSI ignition module is not working or failure to ignite.FRONT BURNER VALVE FAULTIndicates front gas valve is not working, no gas is turned on, or flameout…FRONT DOOR NOT CLOSEDA front door is open when it should be closed.FRONT NOT DOWNDryer is tilted back (N/A for non-tilt model).FRONT SAIL SWITCH CLOSED FAULTFront sail switch is closed when it should be open.FRONT SAIL SWITCH OPEN FAULTFront sail switch is open when it should be closed.HotPossible overheating conditionLINT DRAWER OPENIndicates the lint drawer is open and needs to be closed.LOW VOLTAGE FAULTIndicates power has dropped below operating values and the dryer will shut down.OFFBad coin lockout program has been tripped.PUSHAmount to start has been insertedREAR BURNER HI-LIMIT FAULTIndicates the temperature disk in the rear burner has opened (N/A for this…REAR BURNER IGNITION CONTROL FAULTRear ignition module is not working or failure to ignite (N/A for this model).REAR BURNER VALVE FAULTIndicates rear gas valve is not working, no gas is turned on, or flameout…REAR DOOR NOT CLOSEDA rear door is open when it should be closed.REAR NOT DOWNDryer is tilted forward (N/A for non-tilt model).REAR SAIL SWITCH CLOSED FAULTRear sail switch is closed when it should be open (N/A for this model).
View all 34 error codes

Service modes (8)

  • DSI Module Diagnostic via LED Indicator["Start the dryer and initiate a call for heat.","Observe the DSI module LED indicator in the upper…
  • DSI Module Lock-Out ResetWhen DSI module is in LOCK-OUT mode (red LED stays on continuously), open and close the main door…
  • DSI Module Self-DiagnosticsOn a call for heat, 24 VAC is applied to the DSI module TH and GND terminals
  • DSI System Functional Check["Reestablish power to the dryer after installing replacement DSI module.","Start the drying…
  • Phase 5 Microprocessor Functional Check["Reestablish power to the dryer after installing replacement microprocessor board.","Start the…
  • Phase 5 Microprocessor Hot ResetWhen display reads 'Hot', wait for temperature to drop below 220°F (104°C), then press the…
  • Phase 5 OPL System DiagnosticsThe Phase 5 OPL microprocessor controller automatically monitors all major circuits including door…
  • PLC Auxiliary Keypad Input Functions["Short pins #1 to #5 of the 6-pin connector for CLEAR/STOP function.","Short pins #1 to #2 to run…

Full entry steps, exit procedures, and test sequences are available in Max.