Model reference
Caloric DUR-208-19-OK
Dishwasher
3 documents120 error codes45 service modes
Available documentation
Service Manual
- Instruction Sheet - 854371916 pg
Installation Guide
- Installation Instructions16 pg
- Instrucciones de instalacion32 pg
MyPros+ Max
Diagnose your Caloric DUR-208-19-OK.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (120)
CodeMeaning
1c1cShorted key detected on the membrane keyboard.1c2cMembrane keyboard disconnected from the control board.1c4cBoard-to-board communication failure.1c6cEEPROM hardware fault.1c7cControl not calibrated.1c81EEPROM CRC error in Cook Profile data.1c8cEEPROM CRC error in User Options data.1d11Unlocked runaway oven temperature exceeding 600°F.1d21Locked runaway oven temperature exceeding 950°F.3d11Oven temperature sensor circuit is open.3d21Oven temperature sensor circuit is shorted.3d41Meat probe circuit is shorted.3d51Meat probe not calibrated.4d11Door switch not closed when door is locked.4d21No cooling fan rotation detected.4d31Cooling fan is on when it should be de-energized.4d41Cooling fan overspeed condition detected.4d51Door switch circuit fault.9d11Door latch will not lock.9d21Door latch will not unlock.9d31Door latch reports both locked and unlocked simultaneously.CAAverage current limit trip; a 2-second average current draw greater than 5.55…CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…ErProcessor reset error; the control failed to save cycle information during a…F0-0No fault present.F1Control malfunction (indicates a shorted input key for pad malfunction).F1 E0Oven user interface failure.F1 E1Internal Oven Appliance Manager (AM) error.F1 E4Microwave Oven Relay Error.View all 120 error codes
F1 E5Microwave Oven Inverter Error.F1 E6Microwave Generation Error.F1-1Oven temperature above 650°F (343°C) in bake mode.F1-3Oven temperature above 950°F (510°C) during a clean cycle.F1-5Cancel pad not responding.F1-7Membrane disconnected.F1-8Shorted key (pad) in membrane switch.F1-9Internal control communication errors.F1-ALock/unlock switch state not advancing to control.F1-COven door switch state not advancing to control.F1-EControl not calibrated.F1-E0Oven user interface failure.F1-E1Internal oven ACU (Appliance Control Unit) error.F1-E4Microwave oven relay 4903 error.F1-E5Microwave oven inverter error.F1-E6Microwave generation error.F1-FJumper not removed from printed circuit board (PCB).F1-HEEPROM error.F1-NInternal voltage for slave micro incorrect.F1E1Indicates a Cycle Control Unit (CCU) problem.F2Oven over temperature condition detected for at least 16 seconds.F2 E0Keypad disconnected from User Interface.F2 E1Stuck or shorted key on keypad.F2-E0Keypad disconnected.F2-E1Stuck or shorted keypad.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F2E2User Interface Software Error 1F2E3User Interface Software Error 2F3Open wire lead in sensor harness, bad harness/sensor connection, or sensor…F3 E0Main oven temperature sensor open or shorted.F3 E3Meat probe connector jack or meat probe shorted.F3-1Open or shorted oven temperature sensor.F3-E0Main oven sensor open or shorted.F3-E3Meat probe connector jack or meat probe shorted.F3E1Exhaust thermistor is open; temperature drops below 18°F (> 50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (< 500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistor are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4Sensor resistance too low (below 500 ohms); possible short in sensor wire…F4 E1Microwave oven cavity and magnetron temperature sensor error.F4 E2Magnetron temperature sensor error.F4 E4Microwave oven humidity sensor error.F4 E5Microwave oven inverter error.F4 E8Inverter over temperature.F4 E9Inverter and Magnetron over temperature.F4-E1Microwave cavity temperature sensor error.F4-E2Magnetron temperature sensor error.F4-E4Microwave oven humidity sensor error.F4-E8Inverter over temperature.F4-E9Inverter and magnetron over temperature.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted air flow that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F5Control malfunction.F5 E0Door and latch switch do not agree.F5 E1Latch not operating.F5-E0Door and latch switch do not agree.F5-E1Latch not operating.F6 E4User Interface / Appliance Manager state status mismatch.F6 E6Oven user interface or oven appliance manager lost communication.F6 E8Lost communications with Microwave Oven Appliance Manager.F6 EAOver temperature (two contextsF6-E0Oven user interface lost communication.F6-E1Over temperature.F6-E4User interface / Appliance manager state status mismatch.F6-E6Oven appliance manager lost communication.F6-E8Lost communications with microwave oven appliance manager.F6E1Communication error from UI to CCUF6E2Communication error from CCU to UIF7Indicates a shorted input key for at least 32 seconds (door lock malfunction).F8Shorted meat probe.F9Door lock or oven door not completely closed.F9 E0Product not wired correctly.F9-1Oven door will not lock.F9-2Oven door will not unlock.F9-3Oven door status is both locked and unlocked.F9-E0Product not wired correctly.FFOven temperature is above 585°F and door circuitry has a problem after 16…L2Low L2 voltage (less than 50V) detected at the CCU.LdLong drain; it takes longer than 5 minutes to pump out water to the point where…LFLong fill; the water fill time exceeded 10 minutes, causing the water valves to…LSLid switch error; the control cannot detect lid switch opening/closing…No DisplayThermal fuse, Copernicus Appliance Manager, or User Interface failure causing…obOff balance; the motor controller detected an unrecoverable off-balance…PFPower failure detected during a running cycle; the washer lost power mid-cycle.SLSuds lock; excessive suds detected and the unit was unable to clean out suds…SrStuck relay; the relay has failed in the closed position so the machine…
Service modes (45)
- Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Cavity Size SelectEnter Diagnostics mode (CANCEL > CANCEL > START), then press '3' or '6' keys to scroll to cavity…
- Component ActivationEnter Diagnostics mode, then touch or scroll to 'Component Activation' in the Diagnostics menu and…
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- Control LockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- Control Reset1
- control_lockoutPress the Back and Setup pads simultaneously for 5 seconds to lock.
- control_reset1
- Customer-Focused Dryness Level Adjustment1
- Demo Mode1
- DiagnosticsPress LOWER OVEN > LOWER LIGHT > OVEN CANCEL, then repeat this sequence 2 more times (total 3 times)
- Diagnostics ModePress CANCEL > CANCEL > START
- Diagnostics Mode 1Within 2 minutes of power up, press CANCEL > CANCEL > START
- Diagnostics Mode 2After 2 minutes of power up, press CANCEL > CANCEL > START
- Display Test1
- display_test1
- Error Code View/ClearEnter Diagnostics mode (CANCEL > CANCEL > START), then press '3' or '6' key to scroll to Faults…
- Error DiagnosticsEnter Diagnostics mode, then touch or scroll to 'Error Diagnostics' in the Diagnostics menu and…
- Faults Access1
- faults_access1
- Install Diagnostics1
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Model SelectionEnter Diagnostics mode, then touch or scroll to 'System Information' and touch 'OK'
- Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Quick Test (TEST mode)1. Ensure clock is previously set to time-of-day. 2. Press and hold the COOK TIME pad. 3. While…
- Quick Test Mode1
- Quick Test Mode (EOC III)1
- quick_test1
- Relay ActivationEnter Diagnostics mode (CANCEL > CANCEL > START), then press numeric '3' or '6' keys to scroll to…
- Sensors & SwitchesEnter Diagnostics mode, then touch or scroll to 'Sensors & Switches' in the Diagnostics menu and…
- Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Service Mode1
- service_mode1
- Setup Options (Factory Default Options)1
- Software Version Display1
- Software Versions Access1
- software_versions_access1
- Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
- Status ScreenEnter Diagnostics mode (CANCEL > CANCEL > START), then press numeric '3' or '6' keys to scroll to…
- System InformationEnter Diagnostics mode, then touch or scroll to 'System Information' in the Diagnostics menu and…
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.