Model reference

Ct Electric CT30E/S

Cooktop

5 documents54 error codes14 service modes

Available documentation

Service Manual

  • Wolf CT/E-2: After Serial 17000000 — Service Manual43 pg
    Covers this model
  • Wolf Original: Prior to Serial 17000000 — Service Manual34 pg
    Covers this model

Wiring Diagram

  • Electric Cooktop (CTE) Series - Wiring Diagrams3 pg
    Covers this model

Parts Manual

  • Wolf Original: Prior to Serial 17000000 — Parts Manual10 pg
    Covers this model
  • Wolf CT/E-2: After Serial 17000000 — Parts Manual6 pg
    Covers this model
MyPros+ Max

Diagnose your Ct Electric CT30E/S.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (54)

CodeMeaning
1Ambient temperature read by the control exceeds the error temperature limit…2Heatsink temperature read by the control exceeds the error temperature limit…3Ambient temperature exceeds the high temperature limit (85°C) and the heatsink…4The reading from the ambient temperature thermistor exceeds the open circuit…5The reading from the heatsink temperature thermistor exceeds the open circuit…6Two or more circuits for the various safety sensors are shorted together.7The element supervisor circuit has failed on or off; the supervisory circuit is…8Communications with the Glass-Touch interface chip have failed; if the…9An error was detected with the global off key.E01Power module ambient temperature has reached or exceeded its temperature limit.E02Power module heat sink temperature has reached or exceeded its temperature…E05Power module ambient thermistor has a value indicating a disconnected sensor.E06Power module ambient sensor is shorted to heatsink sensor.E07The power module informs display board which model it is; if value is…E08Display board is unable to communicate to keyboard.E09Keyboard internally detects communications errors and reports back to display…E10Display board is unable to communicate to power module.E11Power module is unable to communicate to display board; fault only visible on…E13Keyboard internally tests for key opens, shorts, and signal quality issues and…E14Keyboard detects internal EEPROM failure and reports to the display board.E15Keyboard internally recalibrates periodically and reports failures to the…E16Keyboard internally detects communications errors and reports this back to the…E17Failure of the Keep Alive capacitor to discharge after a Keep Alive recovery…E18Power board EEPROM CRC failure; EEPROM records are individually tested and…E19A shorted relay or triac was detected on the power module during run time…E20Power module relay power circuit fault was detected (Element Supervisor Fail).E30Display board detected that the least significant digit of a display bar graph…E50Power module heatsink thermistor has a value indicating a disconnected sensor.E56Power module microcontroller flash memory CRC failure.E57Display board microcontroller flash memory CRC failure.
View all 54 error codes

Service modes (14)

  • diagnostic1
  • diagnostic_mode_1Enter diagnostic mode (LOCK mode + hold OFF Key 5 seconds)
  • diagnostic_mode_15While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 15.
  • diagnostic_mode_2While in diagnostic mode, touch the OFF/ON or '+' Key on the 1200W control to enter Mode 2.
  • diagnostic_mode_3While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 3.
  • diagnostic_mode_4While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 4.
  • diagnostic_mode_5While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 5.
  • diagnostic_mode_6While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 6.
  • diagnostic_mode_7While in diagnostic mode, touch the '+' Key on the 1200W control to advance to Mode 7.
  • diagnostic_mode_8_to_14While in diagnostic mode, touch the '+' Key on the 1200W control to advance through Modes 8-14.
  • lockPress and hold the LOCK KEY for three seconds
  • showroom1
  • user_options_frequency1
  • user_options_volume1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax