Model reference
Daewoo YDK-50-6B
Air Conditioner
8 documents13 error codes6 service modes
Available documentation
Service Manual
- Service Manual Split System Air Conditioner Model: DSB-183PH60 pg
- Service Manual Split System Air Conditioner Model: DSB-182L59 pg
- Service Manual Split System Air Conditioner Model: DSB-F183L59 pg
- Service Manual Split System Air Conditioner Model: DSB-F154PH59 pg
- Daewoo DSB F182L CDC 1573 Service Manual57 pg
- Service Manual Model: DSB-F182L56 pg
- Service Manual Split System Air Conditioner Model: DSB-F154LH56 pg
- Service Manual Split System Air Conditioner Model: DSB-182LH51 pg
MyPros+ Max
Diagnose your Daewoo YDK-50-6B.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (13)
CodeMeaning
1Room air thermistor or connector fault.1 blinkIndoor coil sensor open or short, OR outdoor coil sensor open or short, OR…1 blink (0.5s interval, 8s cycle)Indoor coil sensor open or short circuit; unit does not work.2Indoor coil thermistor or connector fault.2 blinksGas leak detected2 blinks (0.5s interval, 8s cycle)Outdoor coil sensor open or short, compressor or electrical parts of compressor…3Compressor failure, electrical parts of compressor fault, or gas leak…continuous blinkGas leak detected (refrigerant leak).continuous ON blinkRoom sensor open or shortContinuous ON lamp blinkRoom sensor open or short circuit; unit continues working with room temperature…LED 1 time blinkGas leak detected; unit continuously working.LED 3 times blinkCompressor or electrical parts of compressor error; unit continuously works to…LED 8s blinkRoom sensor open or short circuit, indoor coil sensor open or short, or outdoor…Service modes (6)
- Emergency OperationPress the Emergency/Remote switch on the indoor unit (switch position set to 'Emergency' / GND)
- Self-DiagnosticThe control automatically contains diagnostic tests to verify system integrity
- Self-Diagnostic FunctionThe control automatically runs diagnostic tests to verify system integrity
- Test OperatingDuring the time of test operating, Fan (Indoor, Outdoor) and Compressor run regardless of room…
- Test Operating Mode["During test operating, Fan (Indoor, Outdoor) and Compressor run regardless of room temperature."]
- Test OperationSet the switch on the switch panel to the 'Test' position (or use Test/Emergency/Remote switch…
Full entry steps, exit procedures, and test sequences are available in Max.