3 documents4 error codes6 service modes
Available documentation
Service Manual
- Daewoo ERF 394A EU E Service Manual CDC 143115 pg
- Daewoo ERF 394AI EU E Service Manual CDC 143115 pg
- Service Manual No-frost Combi-refrigerator56 pg
MyPros+ Max
Diagnose your Daewoo ERF-394A/EU.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (4)
CodeMeaning
D1D-SENSOR (defrost sensor) is in short or open circuit condition.D2Defrost heater is off by exceeding time limit (80 min), indicating heater or…R1R-SENSOR (refrigerator sensor) is in short or open circuit condition.RTRT-SENSOR (room temperature sensor) is in open or short circuit condition.Service modes (6)
- Forced Defrost["Press and hold the TEMP CONTROL button for over 5 seconds continuously."]
- Forced Defrost (ERF-..4A models)Press TEMP CONTROL button and hold for over 5 seconds continuously.
- Forced Defrost (ERF-..7A models)Press CONTROL button and hold for 5 seconds continuously.
- Short Circuit Test (Compressor & Fan Continuous Run)["Press the TEMP CONTROL button 30 times continuously."]
- Short Circuit Test (ERF-..4A models)Press TEMP CONTROL button 30 times continuously.
- Short Circuit Test (ERF-..7A models)Press TEMP CONTROL button 30 times continuously.