Model reference

Edgestar CWD1550BL

Washer

1 document30 error codes1 service mode

Available documentation

Service Manual

  • EdgeStar Combo Washer Dryer Service Manual37 pg
    Covers this model
MyPros+ Max

Diagnose your Edgestar CWD1550BL.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (30)

CodeMeaning
E10After 7 minutes, the water level doesn't change with valves openE11Significant water remains in the unit when unit is in standby or at end of…E12Water level in drum exceeds appropriate level for alarm (overflow condition).E20The main PCB doesn't receive pump signal.E21After 3 minutes, the water level doesn't change with pump started (drain…E30Door will not lock after 3 attempts.E31Door will not unlock after 3 attempts.E33The main PCB is not receiving the water switch (water level sensor) signal.E34Temperature sensor on water heater open circuit.E35Temperature sensor on water heater short circuit.E36Water heater will not work due to failed temp sensor or heater.E37Drum drying outlet temperature sensor failed; drying function will not work.E38Drum drying inlet temperature sensor failed; drying function will not work.E3ADrying heater open circuit; drying function will not work.E40EEPROM failedE50/E52Inverter PCB overload; unit can't work.E50/E53Inverter module temperature failure; unit can't work.E50/E55Motor speed signal lost; unit will stop operation.E50/E56Motor temperature over-protection; unit will stop operation.E50/E57Inverter connection failure; unit will stop operation.E50/E58Inverter module temperature failure / inverter module failure; unit will stop…E50/E5AConnection failure between inverter module and main control PCB; unit will stop…E50/E5BInverter module failure; unit will stop operation.E50/E5COver voltage on inverter module; unit will stop operation.E50/E5DLow voltage on inverter module; unit will stop operation.E50/E5EInverter module failure; unit will stop operation.E64Signal between main PCB and inverter PCB is abnormal; unit will stop operation.E70Button blocked/stuck; unit can't work.E80The main PCB cannot get signal from display PCB; unit can't work.E81The main PCB cannot get signal from display PCB; unit can't work.

Service modes (1)

  • Test Mode["Empty and drain the machine; ensure no water is left in the drum (run a spin cycle and/or open…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands