Error codes (41)

CodeMeaning
1On the last power up, the power module failed self-test.10The resistance of the PC sensor is outside the normal range (< 660 Ohms).11The current measured for the ambient heater, PC fan and FC fan is lower than…12The current measured for the ambient heater, PC fan and FC fan is higher than…13The low ambient heater is drawing less current than expected14The low ambient heater is drawing more current than expected15The PC fan is drawing less current than expected16The PC fan is drawing more current than expected17The FC fan is drawing less current than expected18The FC fan is drawing more current than expected19Reserved.2The previous 2 defrosts were aborted after 40 minutes.20Flapper heater current low.21Flapper heater current is high.22The resistance of the PC sensor 2 is outside the normal range (> 45K Ohms)23The resistance of the PC sensor 2 is outside the normal range (< 660 Ohms)24The resistance of the ice tray sensor is outside the normal range (> 45K Ohms)25The resistance of the ice tray sensor is outside normal range (< 660 Ohms)26Icemaker motor timed out27Icemaker motor current high.28Icemaker solenoid current high.29Icemaker solenoid current low.3The resistance of all the temperature sensors are outside the normal range (>…32Solenoid Driver 1 has failed33Solenoid Driver 2 has failed34Both Solenoid Drivers 1 and 2 have been detected to have a fault.4The resistance of all the temperature sensors are outside the normal range (<…40Icemaker solenoid Transistor 1 short circuit41Icemaker solenoid Transistor 2 short circuit.5The resistance of the FC sensor is outside the normal range (> 45K Ohms).
View all 41 error codes

Service modes (12)

  • Data DownloadPress and hold the MENU button, then press the UP button for four seconds (enter Diagnostic Mode)…
  • Diagnostic ModePress and hold the MENU button, then press the UP button for 4 seconds. The PC temperature will be…
  • Fault HistoryEnter Diagnostic Mode (MENU + UP for 4 seconds), then press UP button six times until HOO is…
  • Flowmeter Calibration (Measured Fill Products)Press and hold the MEASURED FILL button, then press the DOWN button to enter calibration mode
  • Force Icemaker Manual (Measured Fill Products)Press and hold down the MEASURED FILL + UP + DOWN buttons for 4 seconds.
  • Force Icemaker Manual (Non-Measured Fill Products)Press LOCK key first, then DOWN + UP keys and hold all three keys for 4 seconds.
  • Forced DefrostWhile pressing and holding the MENU button, press the DOWN button for 4 seconds.
  • Input/Output StatusEnter Diagnostic Mode (MENU + UP for 4 seconds), then press the UP button three times
  • Sabbath Mode (Measured Fill Products)Press and hold MENU + MEASURED FILL + DOWN buttons for 4 seconds.
  • Sabbath Mode (Non-Measured Fill Products)Press and hold MENU + DOWN + LOCK for 4 seconds.
  • Show Off Mode (Measured Fill Products)Press and hold MENU + DOWN + UP buttons for 4 seconds.
  • Show Off Mode (Non-Measured Fill Products)Press and hold MENU + DOWN + UP buttons for 4 seconds.