Model reference
Fisher & Paykel OR24SDMBGX1
Range, Oven
2 documents5 error codes5 service modes
Available documentation
Bulletin
- Appliance Serial Numbering System for Imported Products & Leaking Griddle Safety Valve15 pg
- Appliance Serial Numbering System & Service Bulletin - Built-In Oven, Freestanding Ranges, and Outdoor Grills15 pg
MyPros+ Max
Diagnose your Fisher & Paykel OR24SDMBGX1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (5)
CodeMeaning
30 F0Temperature probe ST1 short-circuit or damage to temperature probe cable.30 F1Temperature probe ST1 open circuit, damage to cable, or poorly fitted connector.DoLoDoor is locked and oven cavity temperature is above 563°F during or after…F0-00Temperature sensor measurement error during self-clean cycle, possibly due to…F2Transistor for relay one is short circuit or supply voltage is less than 150…Service modes (5)
- EEPROM Table Change (a/b)Turn power off and on
- Full Test ModeTurn on the appliance and within 10 seconds turn the mode selector switch to the 'Self-Clean'…
- Full Test Mode - Level 0Enter Full Test Mode, then set to Level 0 (default level)
- Full Test Mode - Level 1Enter Full Test Mode, then set to Level 1 using buttons 2 & 3 and PLUS/MINUS key.
- Quick TestTurn the selector switch through all settings (0-8) and compare the digital readout with the…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Fisher & Paykel range, oven models
78,000+ service manuals · 160,000+ error codes · 55+ brands