Model reference
Frigidaire FFMS181CQ2
Air Conditioner
1 document49 error codes4 service modes
Available documentation
Service Manual
- Technical Service Manual 2015 Split Type120 pg
MyPros+ Max
Diagnose your Frigidaire FFMS181CQ2.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (49)
CodeMeaning
C5Jumper cap malfunction protectionE1System high pressure protectionE2Anti-freezing protectionE3System low pressure protectionE4Compressor high discharge temperature protection.E5AC overcurrent protectionE6Communication malfunction between indoor and outdoor units.E8High temperature resistant protection (overload/high temperature).EEEEPROM malfunction on outdoor control panel.EULimit/decrease compressor frequency due to high IPM module temperature.F1Indoor ambient temperature sensor open or short circuited.F2Indoor evaporator (tube) temperature sensor open or short circuited.F3Outdoor ambient temperature sensor open or short circuited.F4Outdoor condenser temperature sensor open or short circuited.F5Outdoor discharge temperature sensor open or short circuited.F6Limit/decrease compressor frequency due to overload condition.F8Decrease compressor frequency due to overcurrentF9Decrease compressor frequency due to high discharge temperatureFHLimit/decrease compressor frequency due to anti-freezing protectionFoRefrigerant gathering/recovery modeH0Decrease compressor frequency due to high temperature resistant during heating…H1Defrosting modeH2Static dedusting protection.H3Compressor overload protection.H4System abnormalH5IPM module protection.H6Indoor fan motor locked/blocked protectionH7Compressor desynchronizing (loss of synchronism) protection.HCPFC (Power Factor Correction) protection.L3Outdoor DC fan motor malfunctionView all 49 error codes
L9Power protectionLCCompressor failure start-up (start-up failure).LPIndoor unit and outdoor unit do not match.P0Compressor minimum frequency test state.P1Compressor rated frequency test state.P2Compressor maximum frequency test state.P3Compressor intermediate frequency test state.P5Overcurrent protection of compressor phase current.P7Module temperature sensor circuit malfunction.P8Module high temperature protectionPHDC bus-bar voltage too high.PLDC bus-bar voltage too low.PUCapacitor charging malfunction on outdoor unit.U1Compressor phase current detection circuit malfunction.U3DC bus-bar voltage dips/sagU5Malfunction of complete unit current detection circuit on outdoor unit.U7Four-way valve abnormalU8Zero-crossing inspection circuit malfunction of IDU fan motorU9Outdoor unit zero-crossing detection malfunction / whole unit current testing…
Service modes (4)
- Compulsory Defrosting1
- Failure Remote Calling (Error Code Display via Remote)Push the 'Light' button 4 times within 3 seconds to call out relevant failure protection codes on…
- Forced Running / Fast Test (Indoor Unit)1
- Refrigerant Recovery (Fluorine Collecting)1
Full entry steps, exit procedures, and test sequences are available in Max.
Related Frigidaire air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass