Model reference
Frigidaire 33004
Cooktop
6 documents40 error codes5 service modes
Available documentation
Service Manual
- 30-INCH Freestanding Electric Range11 pg
- 24" Gas Single Wall Oven Service Manual10 pg
- 24" Gas Single Wall Oven Model FGB24L2A10 pg
- SINGLE ELECTRIC WALL OVEN Model No. FEB24S5A8 pg
Tech Data Sheet
- Tech Data Sheet2 pg
Other
- 59953634538 pg
MyPros+ Max
Diagnose your Frigidaire 33004.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (40)
CodeMeaning
C5Jumper cap malfunction protection.d1DRED1 status indicator.d2DRED2 status indicator.d3DRED3 status indicator.E2Anti-freezing protection.E3Communication failure between indoor unit and outdoor unit.E4Compressor exhaust high temperature protection.E5AC over-current protection.E6Communication failure between indoor unit and outdoor unit (or indoor main…E8Anti-high temperature protection.EELoading EEPROM malfunction.EUFrequency limiting (module temperature).F0Refrigerant leakage protection.F1Indoor ambient sensor open or short circuit.F2Indoor tube sensor open or short circuit.F3Outdoor ambient sensor open or short circuit.F4Outdoor tube sensor open or short circuit.F5Exhaust sensor open or short circuit.F6Overload limit / drop frequency.F8Over current limit / drop frequency.F9High exhaust temperature limit / drop frequency.FHAnti-freezing limit / drop frequency.FoGathering refrigerant (refrigerant recovery mode).H1Defrosting (normal operation indicator).H3Compressor overload protection.H4Block or low pressure of refrigerant system.H5IPM protection / Module temperature is too high.H6No feedback of indoor fan motor (blocked protection).HCPFC protection.L3Outdoor DC fan motor malfunction.View all 40 error codes
L9Power protection.LPIndoor unit and outdoor unit doesn't match.LUFrequency limiting (power).P0Compressor minimum frequency in test state.P1Compressor intermediate frequency in test state.P2Compressor rated frequency in test state.P3Compressor maximum frequency in test state.PHHigh PN voltage protection.PLLow PN voltage protection.U74-way valve reversal abnormal.
Service modes (5)
- 8°C Heating functionPress MODE and LIGHT buttons simultaneously in HEAT mode
- Compulsory defrosting1
- Energy-saving function (SE mode)Press MODE and LIGHT buttons simultaneously in COOL mode
- Refrigerant recovery1
- Temperature display switchover (°C/°F)Under OFF status, long press MODE and ∨ buttons simultaneously for 3 seconds to switch temperature…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Frigidaire cooktop models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax