Model reference
GE AM24LP2VHA
Heat Pump
1 document94 error codes12 service modes
Available documentation
Service Manual
- Ductless Multi-Split Heat Pump Service Manual140 pg
MyPros+ Max
Diagnose your GE AM24LP2VHA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (94)
CodeMeaning
1Outdoor EEPROM failure10Malfunction of defrost temperature sensor (Te)11Suction temperature sensor (Ts) failure12Ambient temperature sensor (Ta) failure13Discharge temperature sensor (Td) failure15Communication failure between the indoor and outdoor unit16Lack of refrigerant or discharge pipe blocked174-way valve switching failure18Loss of synchronism detection2IPM overcurrent or short circuit detected by the inverter power module.20Indoor thermal overload.21Indoor unit overload protection (heating mode) / Indoor coil frosted23Module thermal overload24Compressor start failure, over-current25Phase current protection (IPM)26MCU reset27Module current detect circuit malfunction28Liquid pipe sensor failure29Liquid pipe sensor failure30Liquid pipe sensor failure31Liquid pipe sensor failure32Gas pipe sensor failure33Gas pipe sensor failure34Gas pipe sensor failure35Gas pipe sensor failure36Gas pipe sensor failure38Malfunction of module temperature sensor (Tm)39Malfunction of condensing temperature sensor.4Communication failure between the IPM and outdoor PCB.40Liquid pipe sensor failureView all 94 error codes
41Toci temperature sensor failure42High pressure switch open43Low pressure switch open44System high pressure protection45System low pressure protection5Module operated overload (compressor overload protection).6Module low or high voltage8Overheat protection for discharge temperature9Malfunction of the DC outdoor fan motorC1Zero cross signal detected wrong (alternate display for E13 on console).E1Indoor ambient temperature sensor failure.E12Drain system malfunction.E13Zero cross signal detected wrong.E14Indoor fan motor malfunction.E2Indoor coil temperature sensor failure.E4Indoor PCB EEPROM failure.E5Indoor coil frosted / Indoor anti-frosting protection.E7Communication failure between the indoor and outdoor unit.E8Communication fault between the controller and indoor unit.E9Indoor thermal overload / Indoor unit overload protection (heating mode only).ECCommunication error between outdoor and indoor unit detected during wiring…F1IPM overcurrent or short circuit (indoor display code for outdoor error 2).F10Liquid pipe sensor failureF11Loss of synchronism detection (indoor display code for outdoor error 18).F12Outdoor EEPROM failure (indoor display code for outdoor error 1).F13Lack of refrigerant or discharging (hidden indoor code for outdoor error 16).F144-way valve switching failure (hidden indoor code for outdoor error 17).F15Terminal block temp too high (hidden indoor code).F16Liquid pipe sensor failureF17Liquid pipe sensor failureF18Liquid pipe sensor failureF19Module low or high voltage (hidden indoor code for outdoor error 6).F2Compressor start failure, over-current (hidden indoor code for outdoor error…F20Module operated overload / compressor overload protection (hidden indoor code…F21Malfunction of defrost temperature sensor (indoor display code for outdoor…F22Outdoor alternating current, over current protection.F23Phase current protection (IPM) (indoor display code for outdoor error 25).F24Module current detect circuit malfunction (indoor display code for outdoor…F25Discharge temperature sensor failure (indoor display code for outdoor error 13).F26Gas pipe sensor failureF27Compressor current sampling circuit fault.F28Position detection circuit fault of compressor.F29Gas pipe sensor failureF3Communication failure between the IPM and outdoor PCB (indoor display code for…F30Gas pipe sensor failureF31Gas pipe sensor failureF32Gas pipe sensor failureF33Liquid pipe sensor failureF34Outdoor pipe temperature protection in cooling mode.F35Malfunction of module temperature sensor momentary power failure detection…F36Malfunction of condensing temperature sensor (indoor display code for outdoor…F38Toci temperature sensor failure (indoor display code for outdoor error 41).F39High Pressure switch open (indoor display code for outdoor error 42).F4Overheat protection for discharge temperature (indoor display code for outdoor…F40Low Pressure switch open (indoor display code for outdoor error 43).F41System high pressure protection (indoor display code for outdoor error 44).F42System low pressure protection (indoor display code for outdoor error 45).F43Incorrect match between indoor and outdoor unit.F5Module thermal overload (hidden indoor code for outdoor error 23).F6Ambient temperature sensor failure (indoor display code for outdoor error 12).F7Suction temperature sensor failure (indoor display code for outdoor error 11).F8Malfunction of the DC fan motor (hidden indoor code for outdoor error 9).F9MCU reset (indoor display code for outdoor error 26).L0Outdoor air temperature less than -22°F (-30°C).
Service modes (12)
- Auto Restart Enable (Wireless Controller)["Press the Sleep button 10 times within 5 seconds.","4 beeps confirms enabled."]
- Emergency Run / Test Mode (Wall Mount)["1
- Enhanced Defrost Enable (YR-HG Controller)["1
- Forced Cooling["1
- Forced Defrost (Wired Controller)["Initiate from the wired controller."]
- Forced Defrost (Wireless Controller)["1
- Forced Heating["1
- Indoor Temperature Display Toggle (Highwall Only)["Press the Light button 10 times within 5 seconds."]
- Rated Condition Operations (Factory Testing)["1
- Set Enhanced Defrost["1
- View Hidden Error Code (Indoor Display)["Press and hold the Emergency button for 15 seconds."]
- Wiring Error Check["1
Full entry steps, exit procedures, and test sequences are available in Max.