Model reference
Jenn-Air JES1450CDB1
Range
7 documents24 error codes8 service modes
Available documentation
Tech Sheet
- TechSheet W10844271 RevA48 pg
- Tech Sheet48 pg
Service Flash
- Technical Service Pointer6 pg
Tech Tip
- Instruction Sheet4 pg
- Oven Cleaning Quick Reference Guide2 pg
Quick Reference
- Quick Reference Manual2 pg
- Quick Reference Manual2 pg
MyPros+ Max
Diagnose your Jenn-Air JES1450CDB1.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (24)
CodeMeaning
C-81Induction cooktop over temperature (Type 2 failure).C-82Induction cooktop over temperature (Type 2 failure).C-83Induction cooktop temperature sensor stuck (Type 2 failure).F-12Induction cooktop coil under current (Type 1 failure, affects only one burner).F-21Induction cooktop supply power frequency error (Type 2 failure).F-25Stuck fan on Induction Power System (IPS)F-36Induction cooktop temperature sensor is not working (Type 1 failure).F-37Induction cooktop temperature sensor is not working (Type 1 failure).F-40Induction Power System (IPS) failure (Type 1 or Type 2 failure).F-42Induction cooktop power supply error (Type 2 failure).F-43Induction cooktop under voltage (Type 2 failure).F-47Power supply from Induction Power Control (IPC) to User Interface is missing…F-56Wrong or invalid configuration (Type 3 failureF-58Wrong or invalid configuration (Type 2 failure).F-60User Interface does not work (Type 3 failureF1E0EEPROM Communication ErrorF2E0Keypad DisconnectedF2E1Stuck KeypadF3E0Main Oven Sensor Open or ShortedF3E2Drawer Sensor Open or ShortedF6E1Over TempF8E0Cooling Fan Speed Too LowF8E2Cooling Fan Speed Too HighF9E0MiswiredService modes (8)
- Auto Test (Automatic Diagnostic Test)Enter Diagnostics Mode (CANCEL>CANCEL>START within 5 seconds)
- Auto Test (Automatic Diagnostic)Enter Diagnostics Mode (CANCEL > CANCEL > START within 5 seconds), then press the number 3 or 6…
- Clear Error CodesEnter Diagnostic Mode by pressing CANCEL>CANCEL>START within 5 seconds
- Control ResetEnter Diagnostics Mode (CANCEL > CANCEL > START within 5 seconds), press the number 3 or 6 keypads…
- Diagnostics ModePress CANCEL > CANCEL > START within 5 seconds.
- Faults Viewing/ClearingEnter Diagnostics Mode (CANCEL > CANCEL > START within 5 seconds), press the number 3 or 6 keypads…
- Temperature CalibrationPress the Settings or Options keypad until 'Temp Calib' is displayed
- Test Mode (Manual Relay Activation)Enter Diagnostics Mode (CANCEL > CANCEL > START within 5 seconds), then press the number 3 or 6…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Jenn-Air range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass