Model reference
Kenmore 79572033112
Refrigerator
2 documents14 error codes9 service modes
Available documentation
Service Manual
- Refrigerator Service Manual83 pg
Installation Guide
- Use & Care Guide48 pg
MyPros+ Max
Diagnose your Kenmore 79572033112.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (14)
CodeMeaning
Er CFAbnormality of BLDC fan motor for mechanic room (condenser fan)Er COCommunication error between MICOM of Main PCB and Display MICOM, caused by poor…Er dHPoor defrosting errorEr dSDefrosting sensor error caused by short or disconnection of the defrosting…Er FFAbnormality of BLDC fan motor for freezerEr FSFreezer sensor error caused by short or disconnection of the freezer sensor.Er gFFlow meter (sensor) defect caused by error of flow meter, water input, low…Er IFAbnormality of BLDC fan motor for ice makingEr ISIcing sensor error caused by short or disconnection of the icemaker sensor…Er ItIce maker kit defect due to electric system error such as motor, gear, Hall IC…Er rFAbnormality of BLDC fan motor for refrigeratorEr rSRefrigerator sensor error caused by short or disconnection of the refrigerator…Er rtRoom temperature sensor error caused by short or disconnection of the room…Er SSPantry sensor error caused by short or disconnection of the pantry sensor.Service modes (9)
- Display Mode["With the refrigerator door open, press and hold the Refrigerator Temp Button and Ultra ICE Button…
- Error Code Check["Within 3 hours before the error
- Ice Detecting Sensor Diagnosis["Remove ice bin from compartment.","Close both Fresh Food doors.","Wait 3 minutes.","Open the…
- Icemaker Test Mode["Press and hold the FILL key on the icemaker for about 3 seconds."]
- LED Check Function["Simultaneously press Ultra Ice button and freezing temperature adjustment button for one second."]
- Test 1 Mode["Press the test button on the Main PCB 1 time."]
- Test 2 Mode["Press the test button on the Main PCB 2 times."]
- Test 3 Mode (Forced Defrost)["Press the test button on the Main PCB 3 times."]
- Toggle Display °F / °C["Press and hold the FRZ TEMP and REF TEMP keys at the same time for over 5 seconds."]
Full entry steps, exit procedures, and test sequences are available in Max.
Related Kenmore refrigerator models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax