Model reference
Lg Samsung MH052FECA
Air Conditioner
3 documents31 error codes10 service modes
Available documentation
Service Manual
- Samsung MH080FXCA4A Service Manual108 pg
- Free Joint Multi Air Conditioner Service130 pg
Installation Guide
- LG Samsung NJ030MHXCA Precaution2 pg
MyPros+ Max
Diagnose your Lg Samsung MH052FECA.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (31)
CodeMeaning
E101Communication errorE121Indoor unit room temperature sensor error (open or short).E122Indoor unit heat exchanger in temperature sensor error (open or short).E123Indoor unit heat exchanger out temperature sensor error (open or short).E128Try-run mode self-diagnostic error (evaporator pipe in sensor related).E129Try-run mode self-diagnostic error (evaporator pipe out sensor related).E154Indoor unit fan motor error (below 450RPM for 15 minutes).E161Error of mixed operationE162Indoor unit EEPROM error.E163Indoor unit EEPROM option error (option not set up or option data error).E190Failure of pipe check operationE199No pipe check operation performed after installation through auto addressing…E201Communication error between outdoor and indoor unitE202Communication error caused by outdoor unit communication part trouble or indoor…E203Outdoor communication error between outdoor main PCB and sub PCB.E221Outside temperature sensor error (short/open)E230Compressor OLP sensor error (short/open)E237Condenser out sensor error (short/open)E246Try-run mode self-diagnostic error.E251Condenser temperature sensor error (short/open)E261Try-run mode self-diagnostic error.E320Compressor OLP sensor error (short/open)E401Outdoor unit freezing (compressor stop)E404Outdoor unit overloadE416Outdoor unit high discharge temperatureE419Try-run mode self-diagnostic error.E422Try-run mode self-diagnostic error.E440High temperature (over 30°C) of outdoor in heating modeE441Low temperature (under -10°C) of outdoor in cooling modeE458Outdoor fan error.View all 31 error codes
Service modes (10)
- Cool Mode Try-Run["Push K2 button on outdoor display PCB three times."]
- Heat Mode Try-Run["Push K2 button on outdoor display PCB once."]
- Option Setup Mode["Step 1: Remove batteries from remote control.","Step 2: Press the temperature button…
- Option Setup Mode (Indoor Unit via Remote Control)1
- Pipe Check Operation (Auto Addressing)1
- Pipe Checking Operation (Auto Addressing Mode)["Turn on outdoor unit and wait 60 seconds (DIS01 will show 00-01-02-...15-00).","E199 will display…
- Pump Down Mode["Push K2 button on outdoor display PCB (specific number of pushes as indicated on PCB display…
- Refrigerant Charging Mode["Push K2 button on outdoor display PCB (specific number of pushes as indicated on PCB display…
- View Mode (Outdoor PCB Data Display)Press K4 button on outdoor display PCB repeatedly to cycle through data indices 0-15.
- View Mode (Outdoor PCB Display)["Press K4 key on the outdoor display PCB repeatedly to cycle through display data indexes (0-15)."]
Full entry steps, exit procedures, and test sequences are available in Max.