Model reference
Magic Chef U83EY-1G-11
Cooktop
5 documents24 error codes10 service modes
Available documentation
Tech Sheet
- Tech Sheet 8543719 110 2506650016 pg
Service Manual
- Instruction Sheet - 854371916 pg
Installation Guide
- Installation Instructions77 pg
- Installation Instructions60 pg
- Installation Instructions9 pg
MyPros+ Max
Diagnose your Magic Chef U83EY-1G-11.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (24)
CodeMeaning
CAAverage current limit trip; a 2-second average current draw greater than 5.55…CCCZT temperature thermistor closed circuit (short) detected.CECommunications error; breakdown in communication between the machine controller…CIInstantaneous current limit trip; a spike of 26 Amps was detected instantly at…ErProcessor reset error; the control failed to save cycle information during a…FCZT fan performance failureF1E4Microwave ACU PCBA failure.F2E1Stuck key failure on the touch panel.F4E4Humidity sensor error.F8E5Exhaust air temperature detection failure.HCZT heater installation errorHiFan running too fast during diagnostic fan test.LdLong drain; it takes longer than 5 minutes to pump out water to the point where…LFLong fill; the water fill time exceeded 10 minutes, causing the water valves to…LoFan running too slow during diagnostic fan test.LSLid switch error; the control cannot detect lid switch opening/closing…obOff balance; the motor controller detected an unrecoverable off-balance…OCCZT temperature thermistor open circuit detected.OPOpen thermistor input detected during diagnostic service test.PATest passedPFPower failure detected during a running cycle; the washer lost power mid-cycle.SHShorted thermistor input detected during diagnostic service test.SLSuds lock; excessive suds detected and the unit was unable to clean out suds…SrStuck relay; the relay has failed in the closed position so the machine…Service modes (10)
- Automatic Service DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Console Keypad and LED TestControl must be in Off state. Perform Key Dance within 5 seconds
- CZT Test Mode["Open the refrigerator door and tape the door switch closed.","The CZT control display should be…
- Diagnostic Control Mode["Open the fresh food door.","Tape the fresh food door switch in the closed position.","Press Power…
- Diagnostics Mode / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL button to reach standby (colon…
- Manual DiagnosticsControl must be in Off state. Perform Key Dance within 5 seconds
- Nutate and Recirculate TestControl must be in Off state. Perform Key Dance within 5 seconds
- Showroom Mode (SH)["Enter Diagnostic Control Mode.","Use FZ up & down selector to select Mode SH."]
- Spin and Drain TestControl must be in Off state. Water should be present in the unit. Perform Key Dance within 5…
- Water Inlet and Dispenser Valve Operating PS TestControl must be in Off state. Perform Key Dance within 5 seconds
Full entry steps, exit procedures, and test sequences are available in Max.
Related Magic Chef cooktop models
78,000+ service manuals · 160,000+ error codes · 55+ brands