Model reference

Magic Chef M15E-5B

Microwave

4 documents37 error codes13 service modes

Available documentation

Tech Sheet

  • Tech Sheet16 pg
    Covers this model

Service Manual

  • MICROWAVE OVENS Service Professional Seminar44 pg
    Covers this model
  • Job Aid - Microwave Ovens44 pg
    Covers this model

Tech Tip

  • Instruction Sheet - 854179912 pg
    Covers this model
MyPros+ Max

Diagnose your Magic Chef M15E-5B.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (37)

CodeMeaning
CLrNo error(s) found; system is operating normally.F1EEPROM checksum failure or UL A/D error(s).F1 E0EEPROM communications error.F1 E2UL A/D error(s).F1-E1EEPROM checksum failure.F1-E2UL A/D error(s).F1E1Indicates a CCU (Cycle Control Unit) problem.F2EEPROM communications error or shorted key detected.F2 E0Shorted key detected on keypad/membrane.F2 E1Keytail unplugged.F2-E1Keytail unplugged from control.F2E1Indicates a stuck button (depressed for over 20 seconds) or UI mismatch; only…F3Oven sensor opened, oven sensor shorted, BAKE/BROIL range over temperature, or…F3 E0Oven temperature sensor opened (open circuit).F3 E1Oven temperature sensor shorted.F3 E2BAKE/BROIL range over temperature.F3 E3CLEAN range over temperature condition.F3-E2BAKE/BROIL range over temperature condition.F3E1Exhaust thermistor is open; temperature drops below 18°F (>50k ohms).F3E2Exhaust thermistor has shorted; temperature above 250°F (<500 ohms).F3E3Inlet thermistor is open; temperature drops below 18°F (>245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (<328 ohms).F3E5Inlet and exhaust thermistors are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in Diagnostic Test Mode.F4E3Restricted/low air flow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the CCU.F5Door and switches do not agree, door latch not operating, or latch error during…F5 E0Door and switches do not agree.
View all 37 error codes

Service modes (13)

  • Customer-Focused Dryness Level Adjustment1
  • Diagnostics ModeWith oven not in cooking, broiling, or cleaning mode, press Cancel/OFF, Cancel/OFF, START. The…
  • Electronic Oven Control Test["1. Unplug the oven.","2. Remove the cabinet.","3. Discharge the HV capacitor with a 20,000 ohm…
  • Factory Test - Dry Agitation / Dispenser Test Cycle["Set Speed Selector switch to Hand Wash position.","Dial the timer into the small 'U' (dry agitate…
  • Install Diagnostics1
  • Last Error Code Recall["Press and hold CANCEL/OFF key for 5 seconds.","Last error code is displayed."]
  • Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
  • Service Diagnostic Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Select any three buttons…
  • Software Version Display1
  • Temperature Adjustment["Press and hold BAKE key for 5 seconds.","Current offset is shown in display as U-00.","Press…
  • Temperature Adjustment (Calibration)["Press and hold BAKE pad for five (5) seconds.","Current offset, if any, is shown in 3-digit…
  • Temperature Adjustment ModePress and hold BAKE key for 5 seconds
  • Temperature Calibration Adjustment["Press and hold BAKE pad for 5 seconds.","Current offset (if any) is shown on 3-digit display; CAL…

Full entry steps, exit procedures, and test sequences are available in Max.