Model reference

Magic Chef 31FK-2X

Range

1 document28 error codes16 service modes

Available documentation

Tech Sheet

  • TECH SHEET16 pg
    Covers this model
MyPros+ Max

Diagnose your Magic Chef 31FK-2X.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (28)

CodeMeaning
d1Dryer door sense error on control board or due to power line interference…d12Motor sense error on control board or due to power line interference; cycles…d13Blocked coin 2 or coin drop control circuit failure; coin recognition and price…d16Not receiving communications from installed debit card reader in Enhanced…d4Dryer motor control circuit error; cycles and customer display disabled until…d5Blocked coin 1 or coin drop control circuit failure; coin recognition and…d9Voltage detected below 185 VAC for 8 seconds.F0Default F codeF1Electronic control malfunction.F1-E0Key held down too long, or key is shorted.F1-E1Keypad keytail not connected.F1-E5CANCEL key drive line open.F1E1No voltage detected at the heater relay; possible motor or heater failure or…F2-E0Temperature sensor opened (R=2875 ohm by spec).F2-E1Temperature sensor shorted (R=825 ohm by spec).F3-E2Oven temp too highF3-E3Oven temp too highF3E1Exhaust thermistor is open or shorted (open if temp drops below 18°F / >50k…F3E2Moisture sensor strip 1 is open or shorted (only appears in service diagnostic…F3E3Inlet thermistor is open or shorted (open if temp drops below 18°F / >245k…F3E5Second moisture sensor strip is open or shorted (Quad Sense models only; only…F4-E1Meat probe malfunctionF5-E0Door is open but latch is locked (door switch open indicating open door, latch…F5-E1Self-clean latch will not lock/unlock.F6E1ACU and HMI have not communicated for a specified amount of time.F6E2WiFi Module has not responded for a specified amount of time.FCE1WiFi Module communications lost.PFPower failure occurred while the dryer was running.

Service modes (16)

  • Bake Temperature Offset Adjustment1
  • Cavity Size ProgrammingWithin 60 seconds of power up, press the following touchpads in order
  • Component Activation / Quick Service Cycle (LCD in Door Models)["Enter Service Diagnostic Mode (LCD in Door) first.","From the DIAGNOSTICS HOME screen, scroll…
  • diagnosticEnter set-up mode (remove access door key, turn, and lift to remove access door; unplug dryer, open…
  • Diagnostic Mode["Enter the set-up mode first (see set-up mode entry).","While in any of the set-up codes 1 through…
  • Fahrenheit to Celsius ConversionPress the BROIL pad for 5 seconds
  • Fault Code History RecallPress and hold the '0' key to access previous fault codes
  • helpWhile in special pricing option step 2.XX (or while dAS displays if operating with Maytag Data…
  • Help Mode["Enter the set-up mode first.","Navigate to special pricing option step 2.XX (or while dAS…
  • Key Activation & Encoder Test (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
  • Service Diagnostic Mode (Console Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Select any three (3)…
  • Service Diagnostic Mode (LCD in Door Models)["Ensure the dryer is in standby mode (plugged in with all indicators off).","Open and close the…
  • Service Test Mode (Console Models)["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
  • set-upInsert access door key, turn, and lift to remove access door
  • Set-up Mode["Insert access door key, turn, and lift to remove access door.","Unplug dryer or disconnect…
  • Software Version Display (Console Models)["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass