2 documents73 error codes32 service modes

Available documentation

Tech Sheet

  • Fiche Technique - 830441512 pg
    Covers this model

Service Manual

  • Technical Education Job Aid 4317418 KAC-50 27˝ & 30˝ Electric Built-in Single Oven66 pg
    Covers this model
MyPros+ Max

Diagnose your Magic Chef 31FY-2X-EC.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (73)

CodeMeaning
d13The Coin 2 sensor is detected as blocked; coin vault may be full or sensor may…d16No communication from Gend5The Coin 1 sensor is detected as blocked; coin vault may be full or sensor may…d9Incoming voltage detected below 185 VAC (low voltage).F0 E5Off balance load detected during cycle operation.F01Indicates a main control fault.F03Main control detects an out of range pressure signal from the pressure…F04Accelerometer failureF07Main control cannot determine position of shifter (shifter system failure).F0E0No failure (GOOD)F1 E1ACU (Appliance Control Unit) fault detected.F1 E4HMI (Human Machine Interface) fault detected.F1 E6Voltage input fault detected by the control.F11Indicates a fault of the motor control section of the main control.F1E0Internal failureF1E1Internal failureF2 E1Stuck keypad errorF20Water level does not change for a period of time, or water is present but main…F21Water level does not change after the drain pump is on for 10 minutes (long…F22Lid lock has not moved into locked position or motor cannot be powered; lid not…F24Inlet water temperature fault; inlet thermistor is detected to be open or…F25Main control cannot determine speed of basket, or speed changes too quickly…F26Lid is in locked state but lid switch is open; main control cannot detect the…F27Main control senses a water level that exceeds the washer's capacity (overflow…F28Communication failure between MCC (Central Control Module) and MCM (Motor…F29Lid lock has not moved into unlocked position or motor cannot be powered (lid…F2E0Keypad disconnected.F2E1Stuck or shorted key on keypad.F3 E1Thermistor faultF3 E2Pressure sensor fault
View all 73 error codes
F3 E3Inlet water temperature faultF31MCM overheatingF32No fill condition detected; water level does not change.F33Pump disconnectedF34Load detected in washer during the washer clean cycleF3E0Main oven temperature sensor shorted or open.F3E1Lower main oven sensor shorted or openF3E2Warming drawer sensor shortedF3E3Meat probe shorted.F5 E1Dryer door circuit error detected.F5 E3Lid switch faultF5 E4Lid unlock faultF5E0Door and latch switch do not agree.F5E1Door latch not operating.F6 E1ACU to HMI communication faultF6E0Lost communications between user interface and appliance manager.F6E1Cook oven over temperature.F6E2Clean oven over temperature.F6E3Mini oven/warm drawer over temperatureF6E4User interface/appliance manager mismatch.F6E5No cavity size command programmed.F7 E1Basket speed sensor faultF7 E2Motor control faultF7 E5Shifter faultF7 E6Dryer motor circuit error detected.F7 E8Dryer motor sense errorF70Communication failure between CCU and UI; electrical connection is damaged.F71Communication failure between CCU and UI; electrical connection is damaged.F73The User Interface EEPROM identification does not match the expected value in…F74The User Interface EEPROM identification does not match the expected value in…F77Off balance load detected.F8 E1No fillF8 E3Overflow conditionF9 E1Long drainFC E1Model/Serial number not programmed into control.FC E2Model and serial numbers stored in ACU and UI do not match.FC E4USB stick failure (USB full, not detected, or not accessible).FC E5Software update failureFC E6Model setup export failureFC E7Model setup import failureFP E1Coin 1 circuit errorFP E2Coin 2 circuit errorFP E3Card reader communication error.

Service modes (32)

  • Cavity size programming1
  • Clear last error code1
  • Diagnostic mode1
  • diagnostic_mode["Enter setup mode (see setup mode entry).","Navigate to any of the set-up codes 1 through 6 (or…
  • Fahrenheit to Celsius conversionPress OPTIONS and then '1' to toggle temperature between Fahrenheit and Celsius settings.
  • Help Mode["Enter Setup Mode first.","Press HEAVY DUTY keypad while in special pricing option step 2.XX (or…
  • Help Mode (dAS mode)1
  • Help Mode (PD models)1
  • help_mode["Enter setup mode.","Navigate to special pricing option step 2.XX (or while dAS displays if…
  • model_serial_number_menu["Enter Help Mode.","While on the S0 screen, press the HEAVY DUTY keypad.","Use NORMAL keypad to…
  • Model/Serial Number Menu["Enter Help Mode first.","While on the S0 screen press the HEAVY DUTY keypad.","Use NORMAL keypad…
  • Oven temperature calibration adjustment1
  • P-01 Clear Errors["Enter Service Diagnostic Test Modes.","Display shows P-01.","Press START to clear an active error…
  • P-02 Cycle Credit["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-02 is displayed.","Press START…
  • P-03 Service Diagnostic["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-03 is displayed.","Press START…
  • P-04 Manual Diagnostic["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-04 is displayed.","Press START…
  • P-05 Calibration Cycle["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-05 is displayed.","Press START…
  • P-07 UI Diagnostics["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-07 is displayed.","Press START…
  • P-09 Tachometer Verification["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-09 is displayed.","Press START…
  • P-12 Clean Washer Cycle["Enter Service Diagnostic Test Modes.","Press NORMAL Keypad until P-12 is displayed.","Press START…
  • Sabbath Mode activation (one-time enable)1
  • Service Access Code (free-vend models only)1. Open the door. 2. Within 10 seconds, press in sequence
  • Service Diagnostic Test Modes1. Disconnect power and remove service door (PD models) or remove AA1 jumper from IU control board…
  • Service Diagnostic Test Modes (Entry)["1. For coin models
  • Service Diagnostic Test Modes (main entry)["For coin (PD) models
  • Setup Mode["COIN Models
  • setup_mode["PD Models
  • Setup/Configuration Mode (PD models)Insert key into service access door, turn and lift to remove the service access door.
  • Setup/Configuration Mode (PR models)Insert setup card (from card reader manufacturer) into card reader
  • Technician Service Access Code (PR models, free vend only)["Press the POWERWASH, EXTRA RINSE, TEMPERATURE, and DELICATES key pads within 10 seconds."]
  • USB Menu["Enter Help Mode first.","While on the USB screen press the HEAVY DUTY keypad.","Use NORMAL keypad…
  • usb_menu["Enter Help Mode.","While on the USB screen, press the HEAVY DUTY keypad.","Use NORMAL keypad to…

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started