Model reference

Magic Chef BT22RA-4TZ

Range

5 documents59 error codes33 service modes

Available documentation

Tech Sheet

  • Tech Sheet - W10434985 - Rev A8 pg
    Covers this model

Service Manual

  • Service Manual - Freestanding Double Oven Gas Range69 pg
    Covers this model
  • Maytag Gemini Freestanding Double Oven Gas Range Service Manual69 pg
    Covers this model
  • Maytag Freestanding Range Repair Service Manual42 pg
    Covers this model
  • Service Manual - Gas Freestanding Range42 pg
    Covers this model
MyPros+ Max

Diagnose your Magic Chef BT22RA-4TZ.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (59)

View all 59 error codes

Service modes (33)

  • 24 Hour Clock Toggle (H1/M2 Control)Press and hold Cancel and Favorite pads for 3 seconds.
  • 24 Hour Clock Toggle (M1 Control)Press and hold Cancel and Delay pads for 3 seconds.
  • Child Lock OutPress and hold Cancel and Cook & Hold pads for 3 seconds
  • Child Lock Out (H1/M1/M2 Control)["Press and hold Cancel and Cook & Hold pads for 3 seconds.","'OFF' will display where temperature…
  • Clock Display TogglePress and hold Cancel and Clock pads for 3 seconds.
  • Diagnostic Code Display ModePress and hold the AUTOSET pad for 3 seconds at power-up (must be entered only when applying power…
  • Diagnostic Code Display Mode (H1 Control)Press and hold the AUTOSET pad for 3 seconds at power-up
  • Diagnostic Code Display Mode (H2 Control - MGR6875AD*)Press and hold the AUTOSET pad for 3 seconds at power-up
  • Diagnostic Code Display Mode (H3 Control - MGR6775AD*)Press and hold Upper Cancel and Timer for 3 seconds within 5 minutes of power up.
  • Diagnostic Code Display Mode (M1 Control)["Press and hold Up Arrow pad and power up the unit.","Cycle through the codes using the number…
  • Diagnostic Code Display Mode (M1/M2 Control)Press and hold the Up Arrow pad and power up the unit
  • Diagnostic Code Display Mode (M2 Control)["Press and hold Up Arrow pad and power up the unit.","Cycle through the codes using the number…
  • Diagnostics ModePress CANCEL > CANCEL > START within a 5-second period.
  • Diagnostics Test Mode (Relay Checks)While in Diagnostics Mode, press the following keypads to test individual control relays
  • Engineering Test ModePress BAKE pad, enter 100°F using number pads, immediately push and hold BAKE pad for approximately…
  • Engineering Test Mode (H3 Control - MGR6775AD*)Press BAKE pad, enter 100°F using number pads, immediately push and hold BAKE pad for approximately…
  • Factory Default ResetPress and hold Cancel and Keep Warm pads for 3 seconds.
  • Oven Temperature Adjustment (H1 Control)["Press BAKE pad.","Enter 550 on the digit-pad.","Immediately press and hold BAKE pad for 3…
  • Oven Temperature Adjustment (H1/M1/M2 Control)1
  • Quick Test Mode (ERC)1
  • Quick Test Mode (H1 Control)1
  • Quick Test Mode (H2 Control - MGR6875AD*)Press and hold Upper Cancel and Autoset pads for 3 seconds.
  • Quick Test Mode (H2 Control)1
  • Quick Test Mode (H3 Control - MGR6775AD*)Press and hold Upper Cancel and Timer pads for 3 seconds within 5 minutes of power up.
  • Quick Test Mode (M1/M2 Control)1
  • Sabbath ModeHold CLOCK pad for 3 seconds to activate Sabbath mode.
  • Sabbath Mode (H1/M1/M2 Control)["Hold CLOCK pad for 3 seconds to activate Sabbath mode."]
  • Setup Options (Quick Test sub-mode)During Quick Test mode, press the 0 pad
  • Setup Options (within Quick Test Mode)While in Quick Test Mode, press the 0 pad
  • Temperature Adjustment1
  • Temperature Display Toggle (F/C)Press and hold Cancel and Bake pads for 3 seconds.
  • Test Mode1
  • Test Mode (H3 Control - MGR6775AD*)1

Full entry steps, exit procedures, and test sequences are available in Max.

75,000+ service documents · 20,000+ error codes · 100+ brands

Get Started