mypros+
Model reference

Maytag W10156733A

Dryer

1 document25 error codes4 service modes

Available documentation

Tech Sheet

  • Tech Sheet W10156733A Maytag Dryer MEDB200VQ012 pg
    Covers this model
MyPros+ Max

Diagnose your Maytag W10156733A.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (25)

CodeMeaning
AFRestricted air flow condition exists.F:01Primary control failure.F:02Stuck button or user interface mismatch (appears ONLY in diagnostic test mode).F:20No voltage detected at the heater relay (appears ONLY in diagnostic test mode).F:22Exhaust thermistor is open.F:23Exhaust thermistor has shorted.F:24Inlet thermistor is open (appears ONLY in diagnostic test mode).F:25Inlet thermistor is shorted (appears ONLY in diagnostic test mode).F:26Motor drive system failure.F:28Moisture sensor strip is open (appears ONLY in diagnostic test mode).F:29Moisture sensor strip has shorted (appears ONLY in diagnostic test mode).F:30Restricted air flow condition exists (appears ONLY in diagnostic test mode).F:31Low voltage condition (less than 30V) detected (appears ONLY in diagnostic test…F:50No voltage detected at the water valve relay (appears ONLY in diagnostic test…F:70No communication between the machine control and the console electronics.F:71No communication between the machine control and the console electronics.F:72Console electronics failure (F:72 through F:78).F:73Console electronics failure (F:72 through F:78).F:74Console electronics failure (F:72 through F:78).F:75Console electronics failure (F:72 through F:78).F:76Console electronics failure (F:72 through F:78).F:77Console electronics failure (F:72 through F:78).F:78Console electronics failure (F:72 through F:78).L2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.

Service modes (4)

  • Customer-Focused Drying Mode Adjustment["In Standby mode (dryer plugged in but not powered up), press and hold the Dryness Level button…
  • Diagnostic Test Mode["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…
  • Factory Default Reset["Select the Timed Dry cycle.","Press WRINKLE PREVENT, DAMP DRY SIGNAL, WRINKLE PREVENT, DAMP DRY…
  • Manual Load Test["Ensure dryer is in standby mode (plugged in with all indicators off, or with only the Dry…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass