Model reference
Maytag DM15H-14B-R
Microwave
8 documents36 error codes7 service modes
Available documentation
Tech Sheet
- wiring-sheet-W10726336-RevB.pdf2 pg
- Tech Sheet - W11682375 - Rev A2 pg
- Tech Sheet - W11646012 - Rev A2 pg
- Tech Sheet - W11646009 - Rev A2 pg
Tech Tip
- Instruction Sheet - 82691952 pg
- Instruction Sheet - 85312602 pg
- Instruction Sheet - 85244292 pg
- Instruction Sheet - 85245182 pg
MyPros+ Max
Diagnose your Maytag DM15H-14B-R.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (36)
CodeMeaning
F0E1Load detected in drum during Clean Washer cycle.F0E2Oversuds condition detected; washer is running a suds reduction routine.F0E4High temperature error during wash cycle.F0E5Off balance load detected.F1E1ACU Relay failureF1E2MCU over- or under-voltage error.F1E4MW Relay Error 0F2E1Keypad stick errorF3E1Pressure sensor signal missing or out of range.F3E2Wash NTC (thermistor) open or shorted.F3E3Meat probe failure.F3E5Dry NTC fault; dry temperature sensor out of range, open circuit, or short…F3E6Accelerometer error.F3E8IR sensor failureF4E1Wash heater relay error or no feedback signal; ACU cannot detect temperature…F4E2Wash heater relay error.F4E3Hood NTC failureF4E4Humidity sensor failureF4E9MW relay synchro Error 1F4EAToast NTC failureF5E2Door lock failure.F5E3Door unlock failure.F5E4Door not open error.F6E1ACU/HMI communication faultF6E2No communication from the ACU detected by the HMI.F6E3No communication from the MCU detected by the ACU.F7E10Motor disconnected error (also displayed as F7EA).F7E12MC/MCU Overload (also displayed as F7EC).F7E2MC/MCU over temperature error or over current error/internal failure.F7E8MC/Motor over temperature error.Service modes (7)
- Diagnostics Mode["Press Settings
- Fault/Error Code Display["Enter Service Diagnostic Mode; most recent fault code is shown automatically.","Press the 3rd…
- Human-Machine Interface Test["Activate Service Diagnostic Mode first.","Press and release the 1st button used to activate…
- Quick Diagnostic Test["Activate Service Diagnostic Mode first.","Press and release the 2nd button used to activate…
- Service Diagnostic Mode["Ensure washer is in standby mode (plugged in with all indicators off).","Wait 30 seconds after…
- Service Diagnostics Mode1
- Software Version Display["Activate Service Diagnostic Mode first.","Press and hold the 2nd button used to activate Service…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag microwave models
75,000+ service documents · 20,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax