Model reference
Maytag MEG15E-9P-P4
Microwave
7 documents89 error codes24 service modes
Available documentation
Tech Sheet
- tech sheet w11359201 reva2 pg
- tech sheet w11279377 revA20 pg
- Tech Sheet16 pg
- TechSheet W11175370 REVA2 pg
- Tech Sheet - W11193638 - Rev A (EN,FR)24 pg
- Tech Manual24 pg
- Tech Sheet - W10811273 - Rev B5 pg
MyPros+ Max
Diagnose your Maytag MEG15E-9P-P4.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (89)
CodeMeaning
1-1Control detected that pilot relay K2 is stuck in the closed (on) position.1-2Control board memory is damaged or corrupt, or incompatible software components…10-1Detergent/rinse aid dispenser electrical problem10-3Drying fan error2-1User interface button stuck3-1Thermistor/OWI open circuit in the temperature sensing circuit.3-2Thermistor/OWI short circuit3-3OWI calibration failure4-1Wash motor does not run4-2Wash motor4-3Wash motor not running5-1Door switch stuck open5-2Door switch hermetically sealed closed6-1Water inlet6-2Fill valve electrical problem6-3Foam/air in the pump6-4Float switch open6-6Cold water6-7Water inlet6-8Regenerator valve electrical problem7-0Flow meter disconnected or damaged.7-1No heat7-2Heater stuck on8-1Slow drain8-2Drain motor electrical problem8-3Drain stuck on9-1Diverter cannot find position9-2Diverter stuck on9-3Diverter disc missingdLLid Lock FailureView all 89 error codes
dULid Unlock FailureE0No errors present in the ice maker.E1Ice maker errorE2Ice maker errorE3Ice maker errorE4Ice maker errorE5Ice maker errorE6Manufacturing codeErManufacturing codeF 1Pressure Signal Out-of-RangeF 2Keypad/User Interface FailureF 40ATC Thermistor Open/ShortF 41Motor RPS Thermistor Open/ShortF 42Heater in unknown stateF 43Heater is continuously ONF 44Heater cannot be turned ONF 50Motor StalledF 51Motor RPS FailureF 52Motor Stop FailureF 53Motor Control OvertempF 54Motor Control OvercurrentF 72Basket Re-engagement FailureF0E0No error(s) foundF1E0Internal errorF1E1Internal errorF1E3Internal errorF1E4Microwave ACU PCBA failure.F1E5Internal errorF2E0Keypad disconnected from the control.F2E1Stuck key failure on touch panel.F3E0Upper main oven sensor shorted or open.F3E1Lower oven sensor open or shorted.F3E2Warming drawer sensor shortedF3E3Meat probe sensor shorted.F4E1Cavity temperature sensor failure (FC NTC).F4E2Microwave internal temperature sensor fault.F4E4Humidity sensor error.F5E0Door and latch switch do not agree.F5E1Door latch not operating.F6E0Lost communication between user interface and appliance manager.F6E1Cook oven over temperature condition.F6E2Clean oven over temperature condition.F6E3Mini oven/warm drawer over temperatureF6E4User interface and appliance manager mismatch.F6E5No cavity size command programmed.F7E0Water is not high enough or water did not boil fast enough in the steam system.F7E1Boiler over temperature condition.F7E2Boiler NTC temperature sensor out of range.F7E3Improper filter resetF7E4Conductivity sensor not connected.F8E5Exhaust air temperature detection failure from Hood NTC.HCHot, Cold ReversedLdLong DrainLFLong FilllidOpen/Close LidoLOverloadedPoPump OutSdSuds DetectionuLUnbalanced Load
Service modes (24)
- Automatic Diagnostic Test Mode["Ensure washer is not currently running a cycle (in-progress screen should not be…
- Beep TogglePress and hold the Hi Temp button for 3 seconds (a tone sounds).
- Cavity size programming1
- Clear last error code1
- Console and Indicators Diagnostic Test Mode["Ensure washer is not currently running a cycle and LCD is on.","Press the Power/Cancel button and…
- Control LockPress and hold the Control Lock button for 5 seconds to toggle on/off.
- diagnostic["Plug in microwave oven or reconnect power.","Press Cancel button to reach Standby mode (colon ':'…
- Diagnostic / Test Mode["Plug in microwave oven or reconnect power and press the Cancel keypad to standby (colon…
- Diagnostic mode1
- Diagnostic/Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to enter Standby mode (display shows…
- Diagnostics / Test Mode["Plug in microwave oven or reconnect power.","Press CANCEL to reach standby (display shows…
- Diagnostics Menu - Extended Mode1. Enter Diagnostics Mode (OFF, OFF, START). 2. From the Diagnostics Main Menu, access sub-menus
- Diagnostics Mode["Plug in microwave oven or reconnect power and press CANCEL to Standby (':')","Close door, then…
- Error Code ReadingEnter Service Diagnostics mode (1-2-3-1-2-3-1-2-3)
- Fahrenheit to Celsius conversionPress OPTIONS and then '1' to toggle temperature between Fahrenheit and Celsius settings.
- Manual Diagnostic Test Mode["Read and perform steps 1 and 2 of Activation of Automatic Diagnostic Test Mode (enter Service…
- Oven temperature calibration adjustment1
- Pressure Transducer Calibration["Enter Manual Diagnostic Test Mode.","From the Component Activation screen, select the 'Pressure'…
- Quick Advance Mode (Customer Cycles)Press HIGH TEMP
- Rapid Advance Mode (Customer Cycles)Press HIGH TEMP
- Sabbath Mode activation (one-time enable)1
- Saved Fault Codes["Enter Service Mode (Sound and Display > Service Mode > 5, 6, 5, 6 > Enter).","From the Diagnostic…
- Service Diagnostics Cycle1
- Service Diagnostics Mode["Ensure refrigerator is not in lockout mode.","Press SW1 and SW2 simultaneously for 3…