Model reference
Maytag FS-7EVP.000
Range
6 documents26 error codes16 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10118755A12 pg
- Tech Sheet - W10238792 - Rev B_W1023879216 pg
- Tech Sheet - W10156041A16 pg
Tech Tip
- Instruction Sheet - 8533778 - Rev A12 pg
- Instruction Sheet - 854179912 pg
- Instruction Sheet - 397971412 pg
MyPros+ Max
Diagnose your Maytag FS-7EVP.000.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (26)
CodeMeaning
F-01Primary control failure.F-02Stuck button or user interface mismatch (only appears in diagnostic test mode).F-22Exhaust thermistor is open.F-23Exhaust thermistor has shorted.F-26Motor drive system failure.F-28Moisture sensor strip is open (only appears in diagnostic test mode).F-29Moisture sensor strip has shorted (only appears in diagnostic test mode).F-50No voltage detected at the water valve relay (steam models only, only appears…F1E1Primary control failure in the machine control electronics.F2E1Stuck button or user interface mismatch; only appears in service diagnostic…F2E2User Interface Software Error 1F2E3User Interface Software Error 2F3E1Exhaust thermistor circuit is open.F3E2Exhaust thermistor has shorted.F3E3Inlet thermistor is open; temperature drops below 18°F (> 245k ohms).F3E4Inlet thermistor is shorted; temperature above 391°F (< 328 ohms).F3E5Inlet and exhaust thermistor are both open; will occur if P14 connector is not…F3E6Moisture sensor strip is open; only appears in service diagnostic mode.F3E7Moisture sensor strip has shorted; only appears in service diagnostic mode.F4E1No voltage detected at the heater relay; only appears in service diagnostic…F4E3Restricted air flow that may affect dryer performance.F4E4Low L2 voltage (less than 30V) detected at the CCU.F6E1Communication error from UI to CCUF6E2Communication error from CCU to UIL2Low or no line voltage detected (less than 50V) at installation.PFPower failure occurred while the dryer was running.Service modes (16)
- Customer-Focused Drying Mode Adjustment1. Ensure dryer is in standby mode (plugged in with all indicators off, or only DONE indicator on)…
- Customer-Focused Dryness Level Adjustment1
- damp_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
- diagnostic["Set door to open position","Set Temperature switch to Air Fluff","Set End of Cycle Signal switch…
- Diagnostic Test Mode1
- diagnostic_test["Set Fabric Care/Temperature switch to AIR FLUFF","Set Signal switch to HIGH","Set Timer to TIMED…
- Install Diagnostics1
- less_dry_test["Begin with a fully assembled, empty dryer with clean lint screen connected to known good power…
- Loads Test Mode1. Dryer must be in standby mode (plugged in with all indicators off). 2. Within 5 seconds: press…
- Manual Load Test1. Dryer must be in standby mode (plugged in with all indicators off, or with only the Dry…
- Quick Diagnostic TestFrom Service Diagnostics, navigate to Error Diagnostic > Quick Diagnostic Test
- Service Diagnostic Mode1
- Service Diagnostics1. Ensure dryer is in standby mode (plugged in with all indicators off). 2. Select any three…
- Software Version Display1
- UI Component TestFrom Service Diagnostics, navigate to Component Activation > UI Component Test
- User Interface/Control System Test1
Full entry steps, exit procedures, and test sequences are available in Max.