mypros+
Model reference

Maytag FS-7EVP.003

Range

1 document32 error codes21 service modes

Available documentation

Service Manual

  • servicemanual w10881701 l 9164 pg
    Covers this model
MyPros+ Max

Diagnose your Maytag FS-7EVP.003.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (32)

CodeMeaning
1Lower dryer thermistor short sensed11Upper dryer thermistor short sensed12Upper dryer thermistor open sensed13Upper dryer door circuit failure2Lower dryer thermistor open sensed3Lower dryer door circuit failure6Non-volatile memory problem detected with integrity of parameters stored in…8Stuck buttonAFRestricted/low airflow detected that may affect dryer performance.F1E1Motor relay stuck on, indicates an ACU problem.F1E3Incorrect controller installed (electric models only); ACU and/or UI part…F1E5ACU parameter file missing; parameter memory invalid.F2E1User Interface stuck button (depressed for over 20 seconds); only appears in…F2E3UI and ACU model ID parameter mismatch caused by replacement of either the UI…F2E4UI software errorF2E5UI software errorF3E1Exhaust thermistor is open (>50k ohms, below 18°F) or shorted (<500 ohms, above…F3E2Front moisture sensor strip is open or shorted; only appears in service…F3E3Inlet thermistor is open (>245k ohms, below 18°F) or shorted (<328 ohms, above…F3E7Rear moisture sensor strip is open or shorted (Maytag models only); only…F4E1No voltage detected at heater relay 1; heater 1 failure or connector problem.F4E2No voltage detected at heater relay 2; heater 2 failure or connector problem…F4E3Restricted airflow detected that may affect dryer performance.F4E4Low L2 voltage (less than 50V) detected at the ACU (electric models only).F4E5High limitF6E2Communication errorF6E3Communication errorh1A temperature increase has not been detected on the lower dryer and the dryer…h11A shaker assembly neutral fault has been detected; shaker relay is de-energized…HPThermistor reading is out of range and the dryer cycle is interrupted.
View all 32 error codes

Service modes (21)

  • Adjusting Customer-Focused Dryness Level["In standby mode (dryer plugged in but not powered up), press and hold the DRYNESS button for…
  • Clear Diagnostic Codes (cd)1) Enter Diagnostic State
  • Customer-Focused Dryness Level Adjustment["In standby mode (dryer plugged in but not powered up), press and hold the DRY LEVEL button for…
  • Diagnostic StateFrom the Normal Program State on the upper or lower dryer half of the keypad, press the Signal (+)…
  • Diagnostic State (System Check Mode)From the Normal Program State on the upper or lower dryer half of the keypad, press the Signal (+)…
  • Fault Code Display / Clear["1. Activate Service Diagnostic Mode first.","2. Press and release the 3rd button used to activate…
  • Key Activation & Encoder Test["First activate Service Diagnostic Mode.","Press and release the 1st button used to activate…
  • Logic Board Output Self-test (Lo)1) Enter Diagnostic State
  • Membrane Keypad Utility (Pd)1) Enter Diagnostic State
  • Read Sensor Inputs (rd)1) Enter Diagnostic State
  • Reset to Factory Default (rS)["Step 1
  • Reset to Factory Default Conditions (rS)Step 1
  • Sensor Bar Diagnostics (db via rd)1) Enter Diagnostic State ('dd' appears)
  • Sensor Bar Diagnostics (db)Step 1
  • Service Diagnostic Mode["Ensure dryer is in standby mode (plugged in with all indicators off).","Select any three buttons…
  • Service Test Mode["First activate Service Diagnostic Mode.","Press and release the 2nd button used to activate…
  • Software Version Display["First activate Service Diagnostic Mode.","Press and hold the 2nd button used to activate Service…
  • Sub-system Check (Sc)1) Enter Diagnostic State
  • View Cycle Statistics (cS)1) Enter Diagnostic State
  • View Diagnostic Code List (dL)From the Diagnostic State menu, scroll to 'dL' and press Signal (+)
  • View Diagnostic Codes (dL)1) Enter Diagnostic State

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass