Model reference
Maytag MER8800FZ3
Range
4 documents28 error codes11 service modes
Available documentation
Service Manual
- Tech Manual8 pg
- Technical Manual - Cooking Surface Temperature Limits12 pg
Tech Sheet
- Tech Sheet W11503318 REVA2 pg
Quick Reference
- Freestanding Electric Range Quick Start Guide1 pg
MyPros+ Max
Diagnose your Maytag MER8800FZ3.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax
Error codes (28)
CodeMeaning
F1 E5Sensor out of range.F1 E7PCB thermistor open or shorted.F1 E9WIDE queue full.F1-E0EEPROM communication error.F1E0EEPROM communication error.F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F1E9WIDE queue full.F2 E1Stuck key.F2 E2Cancel key error.F2-E0Keypad disconnected.F2E0Keypad disconnected.F2E1Stuck key.F2E2Cancel key error.F3-E0Main oven sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F3E0Main oven sensor open or shorted.F3E2Warming drawer sensor open or shorted.F5 E0Door and switches do not agree (Clean modeF5E0Door and switches do not agree (Clean modeF6 E1Over temperature during cook mode.F6 E2Over temperature during clean mode.F6 E3Over temperature in warming drawer.F6E1Over temperature during cook mode.F6E2Over temperature during clean mode.F6E3Over temperature in warming drawer.F9 E0Mis-wired house or range.F9E0Mis-wired house or range.Service modes (11)
- Diagnostics Mode (Auto Test)["Press CANCEL","Press CANCEL","Press START (display shows 'TEST ON' with cavity temperature and…
- Diagnostics Mode / Auto Test1
- DISPLAY["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 5 (DISPLAY)"]
- ENG MODE["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 2 (ENG MODE)","Press START…
- FAULTS["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 7 (FAULTS)"]
- RELAY USAGE["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 8 (RELAY USAGE)"]
- Temperature Adjustment["Press OPTIONS until 'Temp Calib' is displayed","Press numeric '3' or '6' keypads to adjust…
- TEST MODE["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 3 (TEST MODE)","Press the…
- TEST ON (Relay Checks)["Press CANCEL","Press CANCEL","Press START (display shows 'TEST ON')","Press designated key for…
- USAGE["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 1 (USAGE)"]
- VERSION["Press CANCEL > CANCEL > START to enter Service mode","Scroll to step 4 (VERSION)"]
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
76,000+ service documents · 19,000+ error codes · 100+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax