Model reference
Maytag MET8775XS02
Range
5 documents36 error codes8 service modes
Available documentation
Tech Sheet
- Tech Sheet - W10311746 - Rev A16 pg
- Tech Sheet - W1045710416 pg
Service Manual
- Troubleshooting Gas and Electric Freestanding Range Electronic Controls70 pg
Installation Guide
- Installation Instructions20 pg
- Instruction Sheet1 pg
MyPros+ Max
Diagnose your Maytag MET8775XS02.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (36)
CodeMeaning
E0 F1EEPROM communication error.E0 F2Keypad disconnected.E0 F3Main temperature sensor open or shorted (upper oven).E0 F5Door and latch switches do not agree (Clean mode).E0 F6Lost communications.E0 F9Product is mis-wired.E1 F1Upper RTD uncalibrated.E1 F2Stuck key.E1 F3Main temperature sensor open or shorted (lower oven).E1 F5Door latch not operating (Clean mode).E1 F6Over temperature during cook mode (runaway temperature).E2 F1Lower RTD uncalibrated.E2 F2Stuck key.E2 F6Over temperature during clean mode (runaway temperature).E3 F6Over temperature in warming drawer (runaway temperature).E5 F1Sensor usage out of range.E7 F1PCB Thermistor/Sensor open or shorted.E9 F1WIDE Queue full.F1-E0EEPROM communication error.F1-E1Upper RTD uncalibrated.F1-E2Lower RTD uncalibrated.F1-E5Sensor usage out of range.F1-E7PCB thermistor/sensor open or shorted.F1-E9WIDE Queue full.F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Stuck key.F3-E0Upper oven main sensor open or shorted.F3-E1Lower oven main sensor open or shorted.F5-E0Door and latch switches do not agree during Clean mode.Service modes (8)
- Diagnostics ModePress CANCEL > CANCEL > START
- Diagnostics Mode / Semi Automatic Test ModePress CANCEL > CANCEL > START within 5 seconds
- Faults (Error Code Review)1
- Faults DisplayEnter Diagnostics Mode, then press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads depending…
- Semi Automatic TestEnter Diagnostics Mode, then press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads depending…
- Temperature CalibrationPress SETTINGS/OPTIONS until 'Temp Calib' is highlighted, then follow instructions to see…
- Test Mode1
- Test Mode (manual relay activation)Enter Diagnostics Mode, then press TEMP/TIME '+' or '-' keypads (or Number 3 or 6 keypads depending…
Full entry steps, exit procedures, and test sequences are available in Max.
Related Maytag range models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass