Model reference
Maytag MGR8800HK0
Range
4 documents22 error codes27 service modes
Available documentation
Tech Sheet
- Tech Manual - W1138291416 pg
- tech sheet w11382213 reva2 pg
- Tech Sheet - W10538797 - Rev A8 pg
- Tech Sheet - W10538798 - Rev A (FR)8 pg
MyPros+ Max
Diagnose your Maytag MGR8800HK0.
- Step-by-step diagnostics from the service manual
- Test values, resistance specs, and wiring references
- Verified part numbers when replacement is needed
Start diagnosing
$29/month · Cancel anytime · Or $9.95 3-day pass
Error codes (22)
CodeMeaning
F1-E0EEPROM communication error.F1-E5Sensor out of range.F1-E7PCB thermistor open or shorted.F1E0EEPROM communication error.F1E5Sensor out of range.F1E7PCB thermistor open or shorted.F2-E0Keypad disconnected.F2-E1Stuck key.F2-E2Cancel key error.F2E0Keypad disconnected.F3-E0Main oven temperature sensor open or shorted.F3-E2Warming drawer sensor open or shorted.F5-E0Door and switches do not agree (Clean modeF5-E1Door latch not operating (Clean modeF5E0Door and switches do not agree (Clean modeF5E1Door latch not operating (Clean modeF6-E1Over temperature during cook mode.F6-E2Over temperature during clean mode.F6-E3Over temperature in warming drawer.F6E1Over temperature cook.F6E2Over temperature clean.F6E3Over temperature (warming drawer).Service modes (27)
- Auto Test1
- CONTROL RESET["Enter diagnostic mode
- Diagnostic / Service Mode["Press CANCEL > CANCEL > START.","Display shows 'TEST ON' with oven cavity temperature and door…
- Diagnostics Mode (Auto Test)["Press CANCEL","Press CANCEL","Press START","Display shows 'TEST ON' with cavity temperature and…
- Diagnostics Mode / Service Mode EntryPress CANCEL > CANCEL > START
- DISPLAYEnter Service Mode (CANCEL > CANCEL > START), scroll to step 5 (DISPLAY).
- ENG MODEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 2 (ENG MODE)
- ENG MODE (Engineering Mode)["Enter diagnostic mode
- FAULTSEnter Service Mode (CANCEL > CANCEL > START), scroll to step 7 (FAULTS).
- RELAY USAGEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 8 (RELAY USAGE).
- Service Diagnostic Test Mode1
- Service Mode - AUTO TEST["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 9 (AUTO TEST)"]
- Service Mode - DISPLAY["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 5 (DISPLAY)"]
- Service Mode - ENG MODE["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 2 (ENG MODE)","Press START to…
- Service Mode - FAULTS["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 7 (FAULTS)"]
- Service Mode - RELAY USAGE["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 8 (RELAY USAGE)"]
- Service Mode - TEST MODE["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 3 (TEST MODE)"]
- Service Mode - TEST ON["Press CANCEL","Press CANCEL","Press START"]
- Service Mode - USAGE["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 1 (USAGE)"]
- Service Mode - VERSION["Press CANCEL>CANCEL>START to enter Service Mode","Scroll to step 4 (VERSION)"]
- Temperature Adjustment1
- Temperature Adjustment Mode["Press OVEN LIGHT for 5 seconds (display shows current offset or 0° if no offset)","Press…
- TEST MODEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 3 (TEST MODE)
- TEST MODE (Relay Test)["Enter diagnostic mode
- TEST ON (Relay Checks)Upon entering Service Mode (CANCEL > CANCEL > START), 'TEST ON' is displayed
- USAGEEnter Service Mode (CANCEL > CANCEL > START), scroll to step 1 (USAGE).
- VERSIONEnter Service Mode (CANCEL > CANCEL > START), scroll to step 4 (VERSION).
Full entry steps, exit procedures, and test sequences are available in Max.