mypros+
Model reference

Merloni ElectroméNager TIG664

Cooktop

1 document29 error codes3 service modes

Available documentation

Service Manual

  • Induction - Main Principles29 pg
    Covers this model
MyPros+ Max

Diagnose your Merloni ElectroméNager TIG664.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (29)

CodeMeaning
88General error code displayed during normal operation when a fault is present…E.00Keyboard display error.E.12EEPROM (statistical memory) fault.E.20Key(s) out of action.E.21ON/OFF key out of action.E.22Keyboard temperature sensor in short circuit (CC).E.23Keyboard temperature sensor in open circuit (CO).E.24REL cooking zone temperature sensor in short circuit (CC).E.25REL cooking zone temperature sensor in open circuit (CO).E.26RER element temperature sensor in short circuit (CC).E.27RER cooking zone temperature in open circuit (CO).E.30FRL cooking zone temperature sensor in short circuit (CC).E.31FRL cooking zone temperature sensor in open circuit (CO).E.32FRR cooking zone temperature sensor in short circuit (CC).E.33FRR cooking zone temperature in open circuit (CO).E.34Dissipator temperature sensor of Supplying Generator in short circuit (CC).E.35Dissipator temperature sensor of Supplying Generator in open circuit (CO).E.40Dissipator temperature sensor of Communicating Generator in short circuit (CC).E.54Dissipator temperature sensor of Communicating Generator in open circuit (CO).E.55Synchro signal absent.E.60Communication fault / 12V DC voltage absent.E.70No communication with Supplying Generator.E.71No communication with Communicating Generator.E.72Communication delay with Supplying Generator.E.73Communication delay with Communicating Generator.E.74Communication interference (Checksum) between Supplying Generator and Keyboard.E.75Communication interference (Checksum) between Communicating Generator and…E.76Communication interference (Checksum) between Supplying Generator and Keyboard…E.77Communication interference (Checksum) between Communicating Generator and…

Service modes (3)

  • Diagnostic Display (TIG664)["Press and hold the Stop/Start button until '88' code appears.","While holding Stop/Start, press…
  • Infrared Remote Control Diagnostic (TIG664 only)["Press ON key on remote control to take control (3 beeps).","Press DIA key to start a diagnostic…
  • Remote Control Special Functions (FONC) - TIG664 only["Press ON key to take control (3 beeps).","Press CODE key (1 beep).","Enter code 0123 for level I…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass