Error codes (8)
CodeMeaning
2EInvalid state of EEPROM communication.9EInvalid power source frequency.dfStuck button detected on the display PCB.doThe door is sensed as open while the drum is spinning.FEInvalid power source frequency.heInvalid heating temperature while running the dryer.oDExcess dry time detected.tsThe thermistor resistance is shorted or open.Service modes (5)
- Cycle Count Test ModePress Temp + Mixed Load Bell keys for 3 seconds during Power On state
- Data Display ModeWith Power On (unit can be running), press Adjust Up Key + Adjust Down Key for 7 seconds until it…
- Sensor Bar Touch Data ModePower on dryer, open door and press in door switch
- Service ModePress Mixed Load Bell + Temp for 3 seconds in normal mode until it sends out a beeping sound.
- Software Version Test ModeFrom Service Mode, press Temp key for 3 seconds until beep.