CodeMeaning
C5Jumper connection malfunction protectionE1System high pressure protectionE2Anti-freeze protection of indoor unitE4Compressor discharge high temperature protectionE5Overcurrent / low voltage protectionE6Communication malfunction between indoor and outdoor unitsE8Anti-high temperature protection / overload protection of compressor.EEEEPROM read/write malfunctionEUIPM temperature high limit causing compressor speed reduction.F1Indoor ambient temperature sensor open or short circuit (continuously measured…F2Indoor evaporator tube temperature sensor open or short circuit (continuously…F3Outdoor ambient temperature sensor open or short circuit (continuously measured…F4Outdoor condenser tube temperature sensor open or short circuit (continuously…F5Outdoor compressor discharge temperature sensor open or short circuit…F6Overload limit causing compressor speed reduction.F8Overcurrent causing compressor speed reduction.F9Compressor discharge temperature high causing compressor speed reduction.FHIndoor freeze protectionH0Heating high temperature protection.H1Automatic defrostingH3Compressor overload protectionH4System overload protectionH5IPM module protectionH6Indoor unit DC fan motor does not operateH7Compressor speed reduction protection.HCPFC overcurrent malfunction / protectionL3Outdoor fan module protectionL9High power / over power protectionLCCompressor start-up failure.LPIndoor and outdoor unit match protectionView all 45 error codes
P0Minimum cooling and heating operational status indicator.P1Nominal cooling and heating operational status indicator.P2Maximum cooling and heating operational status indicator.P3Medium cooling and heating operational status indicator.P5Compressor current too highP7Module sensor circuit malfunction.P8Module over temperature protection.PHHigh DC bus voltage protectionPLLow DC bus voltage protectionPUCapacitor charge malfunction.U1Compressor current circuit malfunction.U3Low DC bus voltageU7Four-way valve malfunctionU8Indoor fan speed detection circuit malfunctionU9System current too high / outdoor unit error.
Related Sanyo air conditioner models
78,000+ service manuals · 160,000+ error codes · 55+ brands
Get Started$29/month · Cancel anytime · Or $9.95 3-day pass