mypros+
Model reference

Sub-Zero ICBID-30R

Refrigerator

3 documents72 error codes1 service mode

Available documentation

Service Manual

  • Sub-Zero Service Manual: ICB Integrated Drawer — Service Manual114 pg
    Covers this model

Parts Manual

  • Sub-Zero ICB Integrated Drawer Hydrocarbon (7041360): After Serial 5623000 — Parts Manual25 pg
    Covers this model
  • Sub-Zero Revision 1: Prior to Serial 5622999 — Parts Manual24 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ICBID-30R.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass

Error codes (72)

CodeMeaning
10 0 00Condenser thermistor open circuit detected.10 0 01Condenser thermistor short circuit detected.10 0 02Condenser thermistor unstable signal detected.10 1 00Zone 1 cabinet thermistor open circuit detected.10 1 01Zone 1 cabinet thermistor short circuit detected.10 1 02Zone 1 cabinet thermistor unstable signal detected.10 1 10Zone 1 evaporator thermistor open circuit detected.10 1 11Zone 1 evaporator thermistor short circuit detected.10 1 12Zone 1 evaporator thermistor unstable signal detected.10 2 00Zone 2 cabinet thermistor open circuit detected.10 2 01Zone 2 cabinet thermistor short circuit detected.10 2 02Zone 2 cabinet thermistor unstable signal detected.10 2 10Zone 2 evaporator thermistor open circuit detected.10 2 11Zone 2 evaporator thermistor short circuit detected.10 2 12Zone 2 evaporator thermistor unstable signal detected.10 3 00Zone 3 cabinet thermistor open circuit detected.10 3 01Zone 3 cabinet thermistor short circuit detected.10 3 02Zone 3 cabinet thermistor unstable signal detected.10 3 10Zone 3 evaporator thermistor open circuit detected.10 3 11Zone 3 evaporator thermistor short circuit detected.10 3 12Zone 3 evaporator thermistor unstable signal detected.10 7 00Ambient thermistor on control board open circuit detected.15 1 00Zone 1 compressor relay stuck open; no current detected.15 1 01Zone 1 compressor relay stuck closed; 120V to compressor at all times.15 2 00Zone 2 compressor relay stuck open; no current detected.15 2 01Zone 2 compressor relay stuck closed; 120V to compressor at all times.15 3 00Zone 3 compressor relay stuck open; no current detected.15 3 01Zone 3 compressor relay stuck closed; 120V to compressor at all times.15 4 00Defrost relay stuck open; no power to defrost heater.15 4 01Defrost relay stuck closed; 120V to defrost heater at all times.
View all 72 error codes
15 C 00AC condenser fan relay stuck open; no power to condenser.15 C 01AC condenser fan relay stuck closed; power to compressor at all times.15 U 00Water valve no current detected during activated call for water or dispense.15 U 01Water valve current still detected after valid dispense or ice maker fill…20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal miswire with normal temps; normal defrost temps but…20 2 06Defrost bi-metal miswire with overheat; high temps during defrost and…20 2 50Defrost heater open circuit detected.30 8 05Icemaker no water valve input signal; no signal from icemaker for fill.35 1 00Zone 1 evaporator fan open circuit detected.35 1 33Zone 1 fan speed set too low; fan is running faster than its setting.35 1 34Zone 1 fan speed set too high; fan cannot achieve full speed.35 2 00Zone 2 evaporator fan open circuit detected.35 2 33Zone 2 fan speed set too low; fan is running faster than its setting.35 2 34Zone 2 fan speed set too high; fan cannot achieve full speed.35 3 00Zone 3 evaporator fan open circuit detected.35 3 33Zone 3 fan speed set too low; fan is running faster than its setting.35 3 34Zone 3 fan speed set too high; fan cannot achieve full speed.35 A 00Air filter fan open circuit detected.35 C 00DC condenser fan open circuit detected.35 C 33DC condenser fan speed set too low; fan is running faster than its setting.35 C 34DC condenser fan speed set too high; fan cannot achieve full speed.40 1 00Zone 1 stepper current fault; no current detected.40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault; no cooling detected.40 2 00Zone 2 stepper current fault; no current detected.40 2 40Zone 2 excessive compressor runtime.40 2 87Zone 2 stepper cooling fault; no cooling detected.40 3 40Zone 3 excessive compressor runtime.40 9 40Dispenser active for maximum fill time; possible stuck keys or flooding.40 b 00Baffle stepper current fault.40 b 87Baffle cooling/position fault.45 1 00Zone 1 lights open circuit; main lights relay open.45 1 01Zone 1 lights short circuit; main lights relay closed.45 2 00Zone 2 lights open circuit; main lights relay open.45 2 01Zone 2 lights short circuit; main lights relay closed.90 5 80No UIM (User Interface Module) communications detected.90 H 80High voltage micro (CCM) no communication; communications problems on main…90 H 82High voltage micro (CCM) partial communications; intermittent communications on…90 H 83High voltage micro (CCM) bad communications; communications problems on main…90 H 84High voltage micro (CCM) initialization fault.

Service modes (1)

  • Service Options (Diagnostic Mode)["From the Home Screen, touch the arrow icon to access the Options Screen.","Touch the settings…

Full entry steps, exit procedures, and test sequences are available in Max.

78,000+ service manuals · 160,000+ error codes · 55+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass