Model reference

Sub-Zero ID-36CI

Refrigerator

5 documents94 error codes11 service modes

Available documentation

Service Manual

  • Service Manual Integrated Drawer 1 1010 pg
    Covers this model
  • Service Manual IW-30CI65 pg
    Covers this model
  • Sub-Zero Service Manual: IW-30CI (Vol. 7) — Service Manual5 pg
    Covers this model
  • Sub-Zero Service Manual: Integrated Drawer — Service Manual199 pg
    Covers this model

Parts Manual

  • Sub-Zero Parts Manual: Integrated Drawers — Parts Manual57 pg
    Covers this model
MyPros+ Max

Diagnose your Sub-Zero ID-36CI.

  • Step-by-step diagnostics from the service manual
  • Test values, resistance specs, and wiring references
  • Verified part numbers when replacement is needed
Start diagnosing

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax

Error codes (94)

View all 94 error codes
10 F 12Zone 4 evaporator thermistor is unstable.15 1 00Zone 1 compressor relay stuck open15 1 01Zone 1 compressor relay stuck closed15 2 00Zone 2 compressor relay stuck open15 2 01Zone 2 compressor relay stuck closed15 3 00Zone 3 compressor relay stuck open15 3 01Zone 3 compressor relay stuck closed15 4 00Defrost relay is stuck open, caused by no voltage feedback through the defrost…15 4 01Defrost relay is stuck closed, caused by voltage feedback through the defrost…15 C 00AC condenser fan relay stuck open15 C 01AC condenser fan relay stuck closed15 U 00Water valve no current detected during activated call for water or dispense.15 U 01Water valve current still detected after valid dispense or ice maker fill20 2 00Defrost bi-metal stuck open.20 2 01Defrost bi-metal stuck closed.20 2 05Defrost bi-metal mis-wire with normal temps20 2 06Defrost bi-metal mis-wire with overheat20 2 50Defrost heater open circuit.20 4 50Defrost heater has failed open.30 8 05Icemaker no water valve input signal35 1 00Zone 1 evaporator fan is open.35 1 33Zone 1 fan speed is slower than setting.35 1 34Zone 1 fan speed is faster than setting.35 2 00Zone 2 evaporator fan is open.35 2 33Zone 2 fan speed is slower than setting.35 2 34Zone 2 fan speed is faster than setting.35 3 00Zone 3 evaporator fan is open.35 3 33Zone 3 fan speed is slower than setting.35 3 34Zone 3 fan speed is faster than setting.35 A 00Air filter fan open circuit.35 C 00Condenser fan is open.35 C 33Condenser fan speed is slower than setting.35 C 34Condenser fan speed is faster than setting.40 1 00Zone 1 stepper current fault40 1 09Zone 1 house alarm40 1 40Zone 1 excessive compressor runtime.40 1 87Zone 1 stepper cooling fault40 2 00Zone 2 stepper current fault40 2 09Zone 2 house alarm40 2 40Zone 2 excessive compressor runtime.40 2 87Zone 2 stepper cooling fault40 3 09Zone 3 house alarm40 3 40Zone 3 excessive compressor runtime.40 4 40Zone 4 excessive compressor runtime.40 9 40Dispenser excessive runtime40 b 00Baffle stepper current fault.40 b 87Baffle cooling/position fault.45 1 00Open in Zone 1 light circuit.45 1 01Short in Zone 1 light circuit.45 2 00Open in Zone 2 light circuit.45 2 01Short in Zone 2 light circuit.45 3 00Open in Zone 3 light circuit.45 3 01Short in Zone 3 light circuit.45 F 00Open in Zone 4 light circuit.45 F 01Short in Zone 4 light circuit.90 5 80No UIM (User Interface Module) communications.90 H 80High voltage micro (CCM) no communication90 H 82High voltage micro (CCM) partial communications90 H 83High voltage micro (CCM) bad communications90 H 84High voltage micro (CCM) initialization fault.95 1 00Door #1 excessive open time.95 2 00Door #2 excessive open time.95 3 00Door #3 excessive open time.95 F 00Door #4 excessive open time.

Service modes (11)

  • Clear Faults["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Clear…
  • Current Temperatures["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Temps.","Tap…
  • Manual Component Activation["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Manual…
  • Manual Defrost["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap…
  • Model Configuration["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap…
  • Sabbath Mode["Tap Settings.","Tap Sabbath mode.","Touch and hold the screen for 10 seconds to enable Sabbath…
  • Service Options1
  • Service Options Menu["Tap Settings icon on the Home screen.","Tap Service Options icon.","Enter the password for the…
  • Showroom Mode["On the Home screen, tap the arrow icon to go to Options screen.","Tap Settings.","Tap Service…
  • Temperature Log["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Temp…
  • Zone Temperature Offset["Enter the Service Options Menu (Settings > Service Options > Enter Password).","Tap Offset.","Tap…

Full entry steps, exit procedures, and test sequences are available in Max.

76,000+ service documents · 19,000+ error codes · 100+ brands

Get Started

$29/month · Cancel anytime · Or $9.95 3-day pass · Plus applicable tax